Dlp- A154 Modify A 1+1 Protection Group - Cisco ONS 15454 Series Procedure Manual

Hide thumbs Also See for ONS 15454 Series:
Table of Contents

Advertisement

DLP-A154 Modify a 1+1 Protection Group
Click Apply. The changes are applied. Confirm that the changes appear; if not repeat the task.
Step 5
Note
Return to your originating procedure (NTP).
Step 6
DLP-A154 Modify a 1+1 Protection Group
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
In node view, click the Provisioning > Protection tabs.
Step 1
In the Protection Groups area, click the 1+1 protection group you want to modify.
Step 2
In the Selected Group area, you can modify the following, as needed:
Step 3
See the
Click Apply. Confirm that the changes appear; if not repeat the task.
Step 4
Return to your originating procedure (NTP).
Step 5
Cisco ONS 15454 Procedure Guide, R5.0
18-22
To convert electrical protection groups, see the
Cards from 1:1 Protection to 1:N Protection" procedure on page
This task modifies a 1+1 protection group for any optical port (OC-3,
OC-12, OC-12 IR, OC-48, OC-48 AS, and OC-192).
None
DLP-A73 Create a 1+1 Protection Group, page 17-81
DLP-A60 Log into CTC, page 17-66
As needed
Onsite or remote
Provisioning or higher
Name—Type the changes to the protection group name. The name can have up to 32 alphanumeric
characters.
Bidirectional switching—Check or uncheck.
Revertive—Check this box if you want traffic to revert to the working card after failure conditions
stay corrected for the amount of time chosen from the Reversion Time drop-down list. Uncheck if
you do not want traffic to revert.
Reversion time—If the Revertive check box is selected, choose the reversion time from the
Reversion time drop-down list. The range is 0.5 to 12.0 minutes. The default is 5.0 minutes. This is
the amount of time that will elapse before the traffic reverts to the working card. Traffic can revert
when conditions causing the switch are cleared.
"DLP-A73 Create a 1+1 Protection Group" task on page 17-81
Chapter 18
"NTP-A91 Upgrade DS-1 and DS-3 Protect
11-4.
for field descriptions.
DLPs A100 to A199
March 2007