Cisco ONS 15454 Series Procedure Manual page 201

Hide thumbs Also See for ONS 15454 Series:
Table of Contents

Advertisement

Chapter 6
Create Circuits and VT Tunnels
Stop. You have completed this procedure.
NTP-A187 Create a VT Aggregation Point
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Note
VT aggregation points can be created for circuits on BLSR, 1+1, or unprotected nodes. They cannot be
created for circuits on path protection nodes.
The maximum number of VAPs that you can create depends on the node protection topology and number
Note
of VT1.5 circuits that terminate on the node. Assuming no other VT1.5 circuits terminate at the node,
the maximum number of VAPs that you can terminate at one node is 8 for 1+1 protection and 12 for
BLSR protection.
Step 1
Complete the
aggregation point. If you are already logged in, continue with
Step 2
If you want to assign a name to the tunnel source and destination ports before you create the circuit,
complete the
From the View menu, choose Go to Network View.
Step 3
Step 4
Click the Circuits tab, then click Create.
In the Circuit Creation dialog box, choose VT Aggregation Point from the Circuit Type list.
Step 5
Click Next.
Step 6
Define the circuit attributes
Step 7
August 2005
This procedure creates a VT aggregation point (VAP). VAPs allow multiple
DS-1 (VT1.5) circuits to be aggregated on a single STS on an OC-N, EC1,
DS3, DS3E, DS3i-N-12, DS3XM-6, or DS3XM-12 card. VAPs allow
multiple VT1.5 circuits to pass through cross-connect cards without
utilizing resources on the cross-connect card VT matrix. You also have the
option to route the circuit through a portless transmultiplexing interface.
For portless transmultiplexing configurations, a DS3XM-12 card must be
installed on a node in the network.
NTP-A127 Verify Network Turn Up, page 6-4
As needed
Onsite or remote
Provisioning or higher
"DLP-A60 Log into CTC" task on page 17-66
"DLP-A314 Assign a Name to a Port" task on page
(Figure
Name—Assign a name to the VT aggregation point. The name can be alphanumeric and up to
48 characters (including spaces). Circuit names should be 44 characters or less if you want the
ability to create monitor circuits. If you leave the field blank, CTC assigns a default name to the VAP.
Size—Unavailable for VAPs.
Bidirectional—Unavailable for VAPs.
State—Choose the administrative state to apply to all of the cross-connects in a circuit:
at the node where you will create the VT
6-8):
Cisco ONS 15454 Procedure Guide, R5.0
NTP-A187 Create a VT Aggregation Point
Step
2.
20-8. If not, continue with
Step
3.
6-33