DLPs A100 to A199
DLP-A170 Change Line Transmission Settings for OC-N Cards
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
In node view, double-click the OC-N card where you want to change the line settings.
Step 1
Click the Provisioning > Line tabs.
Step 2
Modify any of the settings described in
Step 3
Table 18-21
Parameter
Port #
Port Name
SF BER
SD BER
Provides
Synch
Enable
Synch
Messages
Send Do
Not Use
Send <FF>
DoNotUse
March 2007
This task changes the line transmission settings for OC-N cards.
None
DLP-A60 Log into CTC, page 17-66
As needed
Onsite or remote
Provisioning or higher
Table
OC-N Card Line Settings
Description
(Display only.) Displays the port
number.
Provides the ability to assign the
specified port a name.
Sets the signal fail bit error rate.
Sets the signal degrade bit error
rate
(Display only.) If checked, the
card is provisioned as a network
element timing reference.
Enables synchronization status
messages (S1 byte), which allow
the node to choose the best
timing source.
When checked, sends a DUS (do
not use) message on the S1 byte.
When checked, sends a special
DUS (0xff) message on the S1
byte.
DLP-A170 Change Line Transmission Settings for OC-N Cards
18-21.
Options
1 (OC-12, OC-48, OC-192)
1-4 (OC-3, OC12-4)
User-defined. Name can be up to
32 alphanumeric/special characters. Blank by default.
See the
"DLP-A314 Assign a Name to a Port" task on
page
20-8.
1E-3
1E-4
1E-5
1E-5
1E-6
1E-7
1E-8
1E-9
Yes
No
Yes
No
Yes
No
Yes
No