Alarms, Errors, and Troubleshooting
TN230X
Did the TN230X come up correctly?
1. Review the LED conditions for the TN230X:
2. If after board insertion or a demand reset:
3. Enter list configuration carrier cabinet carrier on the S8700
Multi-Connect SAT. See the following
page 4-43
4-42
Issue 1 May 2002
State should be present, indicating that A500 port board
insertion was successful. If State is invalid, then the A500
believes that the corresponding port board slot is empty or the port
board is not recognized.
It may be necessary to re-administer the A500 port boards. Refer to
the Cajun A500 Quick Reference for further information.
If Admin Status or State is incorrect, the links will not come up
between a non-IPSI-connected EPN and its controlling
IPSI-connected EPN.
Do the TN230X LEDs (see
normal operational state (any of the following):
— Archangel mode in the EPN
— Standby in the EPN
Do the TN230X LEDs indicate that it is booting?
Do the TN230X LEDs indicate it is downloading its DSPs?
Do the TN230X LEDs indicate that board insertion has not yet
occurred?
Do the TN230X LEDs indicate a maintenance alarm?
(2a).
Table 4-4 on page
4-28) indicate a
Figure 4-21
(1b) and
Figure 4-22 on
555-233-143