Show Port Inlinepower; Set Port Inlinepower - Enterasys SecureStack C2 Configuration Manual

Stackable switches
Hide thumbs Also See for SecureStack C2:
Table of Contents

Advertisement

Syntax
set inlinepower trap {disable | enable} module-number
Parameters
disable | enable
 module‐number
Mode
Switch command, read‐write.
Example
This example shows how to enable PoE trap messaging on module 1:
C2(su)->set inlinepower trap enable 1

show port inlinepower

Use this command to display all ports supporting PoE. 
Syntax
show port inlinepower [port-string]
Parameters
port‐string
Defaults
If not specified, information for all PoE ports will be displayed.
Mode
Switch command, read‐only.
Example
This example shows how to display PoE information for port 
administrative state, PoE priority and class have not been changed from default values:
C2(su)->show port inlinepower ge.2.1
Port
----
ge.2.1

set port inlinepower

Use this command to configure PoE parameters on one or more ports.
Syntax
set port inlinepower port-string {[admin {off | auto}] [priority {critical | high
| low}] [type type]}
Disables or enables PoE trap messaging.
Specifies the module on which to disable or enable trap messaging. 
(Optional) Displays information for specific PoE port(s).
Type
Admin
Oper
----
-----
----
wireless
auto
searching
. In this case, the port's 
ge.2.1
Priority
Class
--------
-----
low
0
SecureStack C2 Configuration Guide 3-29
show port inlinepower
Power(W)
--------
360

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SecureStack C2 and is the answer not in the manual?

Questions and answers

Table of Contents