1
What's New
Changed
Commands
Command
:ACQuire:MODE (see
page
:CALibrate:OUTPut (see
page
:DEMO:FUNCtion (see
page
:DISPlay:VECTors (see
page
:FUNCtion<m>:OPERation
(see
:MARKer:MODE (see
page
:MEASure:SHOW (see
page
:MEASure:WINDow (see
page
:RECall:ARBitrary:[STARt] (see
page
:SAVE:ARBitrary:[STARt] (see
page
:SAVE:WAVeform:FORMat
(see
:SBUS<n>:MODE (see
page
:TRIGger[:EDGE]:SOURce (see
page
:TRIGger:MODE (see
page
:WGEN<w> Commands (see
page
:WMEMory<r> Commands
(see
40
231)
257)
294)
322)
page
358)
394)
457)
481)
615)
624)
page
639)
649)
965)
944)
1055)
page
1099)
Agilent InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
Differences From InfiniiVision 3000 X-Series Oscilloscopes
The ETIMe mode is available with the 1 GHz or 1.5 GHz
bandwidth models.
The TRIG OUT signal can be a trigger output, mask test failure,
or waveform generator sync pulse from either WaveGen1 or
WaveGen2.
The USB and NMONotonic functions are now available with the
DSOXEDK educator's kit license.
The OFF parmeter is available with the 1 GHz or 1.5 GHz
bandwidth models.
The AVERage parameter is available for the Averaged Value
math function.
You can now select the BINary or HEX marker modes.
This now has an OFF state when markers are not in
measurement mode.
This now has a GATE option for gated measurements between
the X1 and X2 cursors.
There is now an option to specify which waveform generator to
recall the arbitrary waveform into.
There is now an option to specify which waveform generator to
save the arbitrary waveform from.
The ALB Agilent module binary format is not supported by the
4000 X-Series oscilloscopes.
The USB mode is now available with the DSOX4USBFL (USB 2.0
Full/Low Speed) or DSOX4USBH (USB 2.0 High Speed) serial
decode and triggering licenses.
You can now trigger on the WGEN1 or WGEN2 outputs or, when
FM or FSK modulation is used, you can trigger on the WMOD
modulating signal output.
The USB mode has been superseded by commands that are
available with the DSOX4USBFL (USB 2.0 Full/Low Speed) or
DSOX4USBH (USB 2.0 High Speed) serial decode and triggering
licenses. See
":SBUS<n>:USB Commands"
With the built-in waveform generator's (with Option WGN
license) two outputs, you can use :WGEN1 and :WGEN2 to
specify which output you are controlling. :WGEN is the same as
:WGEN1. Maximum waveform generator amplitudes and offsets
are also different.
<r> is now from 1 to 4 with four reference waveform memories.
on page 792.