14.4.6

Serial Data Reception (Asynchronous Mode)

Figure 14.8 shows an example of operation for reception in asynchronous mode. In serial
reception, the SCI operates as described below.
1. The SCI monitors the communication line. If a start bit is detected, the SCI performs internal
synchronization, receives receive data in RSR, and checks the parity bit and stop bit.
2. If an overrun error occurs (when reception of the next data is completed while the RDRF flag
is still set to 1), the ORER bit in SSR is set to 1. If the RIE bit in SCR is set to 1 at this time, an
ERI interrupt request is generated. Receive data is not transferred to RDR. The RDRF flag
remains to be set to 1.
3. If a parity error is detected, the PER bit in SSR is set to 1 and receive data is transferred to
RDR. If the RIE bit in SCR is set to 1 at this time, an ERI interrupt request is generated.
4. If a framing error is detected (when the stop bit is 0), the FER bit in SSR is set to 1 and receive
data is transferred to RDR. If the RIE bit in SCR is set to 1 at this time, an ERI interrupt
request is generated.
5. If reception is completed successfully, the RDRF bit in SSR is set to 1, and receive data is
transferred to RDR. If the RIE bit in SCR is set to 1 at this time, an RXI interrupt request is
generated. Continuous reception is possible because the RXI interrupt routine reads the receive
data transferred to RDR before reception of the next receive data has been completed.
Start
1
bit
0
D0
RDRF
FER
Figure 14.8 Example of SCI Operation in Reception
Data
Parity
Stop
bit
bit
D1
D7
0/1
RXI interrupt
request
generated
1 frame
(Example with 8-Bit Data, Parity, One Stop Bit)
Section 14 Serial Communication Interface (SCI)
Start
Data
bit
1
0
D0
D1
RDR data read and RDRF
flag cleared to 0 in RXI
interrupt service routine
Rev. 6.00 Mar 15, 2006 page 345 of 570
Parity
Stop
bit
bit
1
Idle state
D7
0/1
0
(mark state)
ERI interrupt request
generated by framing
error
REJ09B0211-0600