20.4.3

Setting Oscillation Stabilization Time after Clearing Software Standby Mode

Bits STS2 to STS0 in SBYCR should be set as described below.
• Using a Crystal Oscillator:
Set bits STS0 to STS2 so that the standby time is at least 8 ms (the oscillation stabilization
time).
Table 20.3 shows the standby times for different operating frequencies and settings of bits
STS0 to STS2.
• Using an External Clock:
The PLL circuit requires a time for stabilization. Set bits STS0 to STS2 so that the standby
time is at least 2 ms.

Table 20.3 Oscillation Stabilization Time Settings

STS2
STS1 STS0
0
0
0
1
1
0
1
1
0
0
1
1
0
1
: Recommended time setting
Note:
* Setting prohibited
20
Standby Time
MHz
8192 states
0.41
16384 states
0.82
32768 states
1.6
65536 states
3.3
131072 states
6.6
262144 states
13.1
Reserved
16 states *
0.8
Section 20 Power-Down Modes
16
12
10
8
MHz
MHz
MHz
MHz
0.51
0.68
0.8
1.0
1.0
1.3
1.6
2.0
2.0
2.7
3.3
4.1
4.1
5.5
6.6
8.2
8.2
10.9
13.1
16.4
16.4
21.8
26.2
32.8
1.0
1.3
1.6
2.0
Rev. 6.00 Mar 15, 2006 page 501 of 570
6
4
MHz
MHz
Unit
1.3
2.0
ms
2.7
4.1
5.5
8.2
10.9
16.4
21.8
32.8
43.6
65.6
1.7
4.0
µs
REJ09B0211-0600