Figure 10.13 Example Of Data Reception Flowchart (Asynchronous Mode) - Renesas H8/3847R Series Hardware Manual

8-bit single-chip microcomputer super low power
Table of Contents

Advertisement

• Receiving
Figure 10.13 shows an example of a flowchart for data reception. This procedure should be
followed for data reception after initializing SCI3.
Start
Read bits OER,
1
PER, FER in SSR
OER + PER
+ FER = 1?
No
Read bit RDRF
2
in SSR
RDRF = 1?
Yes
Read receive
data in RDR
Continue data
3
reception?
No
Clear bit RE to
0 in SCR3
End

Figure 10.13 Example of Data Reception Flowchart (Asynchronous Mode)

Yes
No
Receive error
4
processing
Yes
(A)
Section 10 Serial Communication Interface
1.
Read bits OER, PER, and FER in the
serial status register (SSR) to determine
if there is an error. If a receive error has
occurred, execute receive error
processing.
2.
Read SSR and check that bit RDRF is
set to 1. If it is, read the receive data
in RDR. When the RDR data is read,
bit RDRF is cleared to 0 automatically.
3.
When continuing data reception, finish
reading of bit RDRF and RDR before
receiving the stop bit of the current
frame. When the data in RDR is read,
bit RDRF is cleared to 0 automatically.
Rev. 6.00 Aug 04, 2006 page 385 of 680
REJ09B0145-0600