Section 10 16-Bit Timer Pulse Unit (TPU)
2. Examples of waveform output operation
Figure 10.6 shows an example of 0 output/1 output.
In this example TCNT has been designated as a free-running counter, and settings have been
made such that 1 is output by compare match A, and 0 is output by compare match B. When
the set level and the pin level coincide, the pin level does not change.
TCNT value
H'FFFF
TGRA
TGRB
H'0000
TIOCA
TIOCB

Figure 10.6 Example of 0 Output/1 Output Operation

Figure 10.7 shows an example of toggle output.
In this example, TCNT has been designated as a periodic counter (with counter clearing on
compare match B), and settings have been made such that the output is toggled by both
compare match A and compare match B.
TCNT value
H'FFFF
TGRB
TGRA
H'0000
TIOCB
TIOCA
Rev. 6.00 Mar 15, 2006 page 200 of 570
REJ09B0211-0600
No change
Counter cleared by TGRB compare match

Figure 10.7 Example of Toggle Output Operation

No change
No change
Time
No change
1 output
0 output
Time
Toggle output
Toggle output