Program/Erase Protection; Hardware Protection; Software Protection; Error Protection - Renesas H8S Series Hardware Manual

16-bit single-chip microcomputer
Hide thumbs Also See for H8S Series:
Table of Contents

Advertisement

Section 18 ROM
18.9

Program/Erase Protection

There are three kinds of flash memory program/erase protection; hardware protection, software
protection, and error protection.
18.9.1

Hardware Protection

Hardware protection refers to a state in which programming/erasing of flash memory is forcibly
disabled or aborted because of a transition to reset or standby mode. Flash memory control register
1 (FLMCR1), flash memory control register 2 (FLMCR2), and erase block register 1 (EBR1) are
initialized. In a reset via the RES pin, the reset state is not entered unless the RES pin is held low
until oscillation stabilizes after powering on. In the case of a reset during operation, hold the RES
pin low for the RES pulse width specified in the AC characteristics section.
18.9.2

Software Protection

Software protection can be implemented against programming/erasing of all flash memory blocks
by clearing the SWE bit in FLMCR1. When software protection is in effect, setting the P1 or E1
bit in FLMCR1 does not cause a transition to program mode or erase mode. By setting the erase
block register 1 (EBR1), erase protection can be set for individual blocks. When EBR1 is set to
H'00, erase protection is set for all blocks.
18.9.3

Error Protection

In error protection, an error is detected when CPU runaway occurs during flash memory
programming/erasing, or operation is not performed in accordance with the program/erase
algorithm, and the program/erase operation is aborted. Aborting the program/erase operation
prevents damage to the flash memory due to overprogramming or overerasing.
When the following errors are detected during programming/erasing of flash memory, the FLER
bit in FLMCR2 is set to 1, and the error protection state is entered.
• When the flash memory of the relevant address area is read during programming/erasing
(including vector read and instruction fetch)
• Immediately after exception handling (excluding a reset) during programming/erasing
• When a SLEEP instruction is executed during programming/erasing
The FLMCR1, FLMCR2, and EBR1 settings are retained, however program mode or erase mode
is aborted at the point at which the error occurred. Program mode or erase mode cannot be re-
Rev. 6.00 Mar 15, 2006 page 478 of 570
REJ09B0211-0600

Advertisement

Table of Contents
loading

This manual is also suitable for:

H8s/2600 seriesH8s/2612 seriesH8s/2612 f-ztat

Table of Contents