Table 11.2 Initial Values Of Tbru To Tbrw And Initial Output - Renesas H8S Series Hardware Manual

16-bit single-chip microcomputer
Hide thumbs Also See for H8S Series:
Table of Contents

Advertisement

Table 11.2 Initial Values of TBRU to TBRW and Initial Output

Initial Value of TBRU to TBRW
TBR = H'0000
H'0000 < TBR ≤ Td
Td < TBR ≤ H'FFFF – 2Td
PWM Output Generation in Operating Modes: In the operating modes, a 3-phase PWM
waveform is output with a non-overlap relationship between the positive and negative phases. This
non-overlap time is called the dead time.
The PWM waveform is generated from an output generation waveform generated by ANDing the
compare output waveform with the dead time generation waveform. Waveform generation for one
phase (the U-phase) is shown here. The V-phase and W-phase waveforms are generated in the
same way.
1. Compare Output Waveform
The compare output waveform is generated by comparing the values in the TCNT counter and
the TGR registers.
For compare output waveform U phase A (CMOUA), 0 is output if TGRUU > TCNT in the T1
interval (when TCNT is counting up), and 1 is output if TGRUU ≤ TCNT. In the T2 interval
(when TCNT is counting down), 0 is output if TGRU > TCNT, and 1 is output if TGRU ≤
TCNT.
For compare output waveform U phase B (CMOUB), 1 is output if TGRU > TCNT in the T1
interval, and 0 is output if TGRU ≤ TCNT. In the T2 interval, 1 is output if TGRUD > TCNT,
and 0 is output if TGRUD ≤ TCNT.
2. Dead Time Generation Waveform
For dead time generation waveform U phases A (DTGUA) and B (DTGUB), 1 is output as the
initial value.
TDCNT0 starts counting at the falling edge of CMOUA. DTGUA outputs 0 if TDCNT0 is
counting, and 1 otherwise.
TDCNT1 starts counting at the falling edge of CMOUB. DTGUB outputs 0 if TDCNT1 is
counting, and 1 otherwise.
Section 11 Motor Management Timer (MMT)
OLSP = 1, OLSN = 1
Positive phase: 1
Negative phase: 0
Positive phase: 0
Negative phase: 0
Positive phase: 0
Negative phase: 1
Rev. 6.00 Mar 15, 2006 page 259 of 570
Initial Output
OLSP = 0, OLSN = 0
Positive phase: 0
Negative phase: 1
Positive phase: 1
Negative phase: 1
Positive phase: 1
Negative phase: 0
REJ09B0211-0600

Advertisement

Table of Contents
loading

This manual is also suitable for:

H8s/2600 seriesH8s/2612 seriesH8s/2612 f-ztat