Section 11 Motor Management Timer (MMT)
Section 11 Motor Management Timer (MMT)
Motor Management Timer (MMT) can output 6-phase PWM waveforms with non-overlap times.
Figure 11.1 shows a block diagram of the MMT.
Note: No MMT is implemented in the H8S/2614 and H8S/2616.
11.1
Features
• Triangular wave comparison type 6-phase PWM waveform output with non-overlap times
• Non-overlap times generated by timer dead time counters
• Toggle output synchronized with PWM period
• Counter clearing on an external signal
• Data transfer by DTC activation
• Output-off functions
• PWM output halted by external signal
• PWM output halted when oscillation stops
• Module stop mode can be set
Rev. 6.00 Mar 15, 2006 page 245 of 570
REJ09B0211-0600