Bit
Bit Name
Initial Value
5
ORER
0
4
FER
0
3
PER
0
Section 14 Serial Communication Interface (SCI)
R/W
Description
R/W
Overrun Error
[Setting condition]
When the next serial reception is completed while
RDRF = 1
[Clearing condition]
When 0 is written to ORER after reading ORER = 1
R/W
Framing Error
[Setting condition]
When the stop bit is 0
[Clearing condition]
When 0 is written to FER after reading FER = 1
In 2-stop-bit mode, only the first stop bit is checked.
R/W
Parity Error
[Setting condition]
When a parity error is detected during reception
[Clearing condition]
When 0 is written to PER after reading PER = 1
Rev. 6.00 Mar 15, 2006 page 325 of 570