20.1.2
Module Stop Control Registers A to C (MSTPCRA to MSTPCRC)
MSTPCR is comprised of three 8-bit readable/writable registers, and performs module stop mode
control. Setting a bit to 1 causes the corresponding module to enter module stop mode. Clearing
the bit to 0 clears the module stop mode.
MSTPCRA
Bit
Bit Name
MSTPA7 *
7
6
MSTPA6
5
MSTPA5
MSTPA4 *
4
3
MSTPA3
MSTPA2 *
2
1
MSTPA1
MSTPA0 *
0
MSTPCRB
Bit
Bit Name
7
MSTPB7
6
MSTPB6
5
MSTPB5
MSTPB4 *
4
MSTPB3 *
3
MSTPB2 *
2
MSTPB1 *
1
MSTPB0 *
0