Section 14 Serial Communication Interface (SCI)
Bit
Bit Name
Initial Value
5
ORER
0
4
ERS
0
3
PER
0
Rev. 6.00 Mar 15, 2006 page 328 of 570
REJ09B0211-0600
R/W
Description
R/W
Overrun Error
[Setting condition]
•
When the next serial reception is completed while
RDRF = 1
[Clearing condition]
•
When 0 is written to ORER after reading ORER = 1
R/W
Error Signal Status
[Setting condition]
•
When the low level of the error signal is sampled
[Clearing condition]
•
When 0 is written to ERS after reading ERS = 1
R/W
Parity Error
[Setting condition]
•
When a parity error is detected during reception
[Clearing condition]
•