Section 21 Electrical Characteristics
21.3.1
Clock Timing
Table 21.4 lists the clock timing
Table 21.4 Clock Timing
Conditions : V
= 4.5 V to 5.5 V, AV
CC
20 MHz, T
range specifications)
Item
Clock cycle time
Clock high pulse width
Clock low pulse width
Clock rise time
Clock fall time
Oscillation stabilization time at
reset (crystal)
Oscillation stabilization time in
software standby (crystal)
External clock output
stabilization delay time
Rev. 6.00 Mar 15, 2006 page 512 of 570
REJ09B0211-0600
= 4.5 V to 5.5 V, V
CC
= –20°C to +75°C (regular specifications), T
a
Symbol
Min.
t
50
cyc
t
15
CH
t
15
CL
t
—
Cr
t
—
Cf
t
20
OSC1
t
8
OSC2
t
2
DEXT
t
CH
φ
Figure 21.2 System Clock Timing
= AV
SS
Max.
250
—
—
10
10
—
—
—
t
cyc
t
Cf
t
t
CL
Cr
= 0 V, φ = 4 MHz to
SS
= –40°C to +85°C (wide-
a
Unit
Test Conditions
ns
Figure 21.2
ns
ns
ns
ns
ms
Figure 21.3
ms
Figure 20.3
ms
Figure 21.3