Interrupts In Smart Card Interface Mode; Table 14.12 Sci Interrupt Sources; Table 14.13 Sci Interrupt Sources - Renesas H8S Series Hardware Manual

16-bit single-chip microcomputer
Hide thumbs Also See for H8S Series:
Table of Contents

Advertisement

Section 14 Serial Communication Interface (SCI)

Table 14.12 SCI Interrupt Sources

Channel
Name
0
ERI_0
RXI_0
TXI_0
TEI_0
1
ERI_1
RXI_1
TXI_1
TEI_1
2
ERI_2
RXI_2
TXI_2
TEI_2
14.8.2

Interrupts in Smart Card Interface Mode

Table 14.13 shows the interrupt sources in Smart Card interface mode. The transmit end interrupt
(TEI) request cannot be used in this mode.

Table 14.13 SCI Interrupt Sources

Channel
Name
0
ERI_0
RXI_0
TXI_0
1
ERI_1
RXI_1
TXI_1
2
ERI_2
RXI_2
TXI_2
Rev. 6.00 Mar 15, 2006 page 376 of 570
REJ09B0211-0600
Interrupt Source
Receive Error
Receive Data Full
Transmit Data Empty
Transmission End
Receive Error
Receive Data Full
Transmit Data Empty
Transmission End
Receive Error
Receive Data Full
Transmit Data Empty
Transmission End
Interrupt Source
Receive Error, detection
Receive Data Full
Transmit Data Empty
Receive Error, detection
Receive Data Full
Transmit Data Empty
Receive Error, detection
Receive Data Full
Transmit Data Empty
Interrupt Flag
ORER, FER, PER
RDRF
TDRE
TEND
ORER, FER, PER
RDRF
TDRE
TEND
ORER, FER, PER
RDRF
TDRE
TEND
Interrupt Flag
ORER, PER, ERS
RDRF
TEND
ORER, PER, ERS
RDRF
TEND
ORER, PER, ERS
RDRF
TEND
DTC Activation
Not possible
Possible
Possible
Not possible
Not possible
Possible
Possible
Not possible
Not possible
Possible
Possible
Not possible
DTC Activation
Not possible
Possible
Possible
Not possible
Possible
Possible
Not possible
Possible
Possible