Section 4 Exception Handling
module registers cannot be read or written to. Register reading and writing is enabled when the
module stop mode is exited.
4.4

Traces

Traces are enabled in interrupt control mode 2. Trace mode is not activated in interrupt control
mode 0, irrespective of the state of the T bit. For details of interrupt control modes, see section 5,
Interrupt Controller.
If the T bit in EXR is set to 1, trace mode is activated. In trace mode, a trace exception occurs on
completion of each instruction. Trace mode is not affected by interrupt masking. Table 4.3 shows
the state of CCR and EXR after execution of trace exception handling. Trace mode is canceled by
clearing the T bit in EXR to 0. The T bit saved on the stack retains its value of 1, and when control
is returned from the trace exception handling routine by the RTE instruction, trace mode resumes.
Trace exception handling is not carried out after execution of the RTE instruction.
Interrupts are accepted even within the trace exception handling routine.
Table 4.3
Status of CCR and EXR after Trace Exception Handling
Interrupt Control Mode
0
2
Legend:
1:
Set to 1
0:
Cleared to 0
—: Retains value prior to execution
4.5

Interrupts

Interrupts are controlled by the interrupt controller. The interrupt controller has two interrupt
control modes and can assign interrupts other than NMI to eight priority/mask levels to enable
multiplexed interrupt control. The source to start interrupt exception handling and the vector
address differ depending on the product. For details, refer to section 5, Interrupt Controller.
Interrupt exception handling is conducted as follows:
1. The values in the program counter (PC), condition code register (CCR), and extended control
register (EXR) are saved to the stack.
2. The interrupt mask bit is updated and the T bit is cleared to 0.
Rev. 6.00 Mar 15, 2006 page 62 of 570
REJ09B0211-0600
CCR
I
UI
Trace exception handling cannot be used.
1
EXR
I2 to I0
T
0