A
B
Measure the voltage between
P/J8988
rotate the encoder,
PL 13.15 Item 19
changes.
Y
N
Install a new stacker encoder sensor,
Install a new finisher PWB,
PL 13.45 Item
Enter
dC330
code 012-060 and 012-061 alternatively. The stacker motor runs.
Y
N
Measure the voltage between
P/J8986
mately +24 VDC.
Y
N
Check the +24VDC circuit. Refer to the
Check the wiring between
P/J8986
short circuit, or a loose or damaged connector. The wiring is good.
Y
N
Reconnect or repair as necessary.
Install a new stacker motor,
PL 13.15 Item
PWB,
PL 13.45 Item
2.
Install a new finisher PWB,
PL 13.45 Item
Status Indicator RAPs
012-211B, 012-212
pin 23 on the finisher PWB and ground. Manually
to actuate the stacker encoder sensor The voltage
PL 13.15 Item
32.
2.
pin 12 and ground. The voltage is approxi-
Wiring
Diagrams.
pins 11 and 12 and the stacker motor for an open or
29. If the fault persists, install a new finisher
2.

012-212 Stacker Tray Upper Limit Failure RAP

BSD-ON:
BSD 13.15 Office Finisher LX Stacker Tray Control
012-212 The stacker has continued to elevate after the defined period of time has passed
since stacker no paper sensor is on during stacker elevation.
Initial Actions
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP
death or injury. Moving parts can cause injury.
Check for obstructions under the tray.
Check the operation of the stacker height sensor,
Check the tray raise/lower mechanism for damage or contamination.
Procedure
Enter
dC330
code 012-264. Actuate stacker height sensor 1. The display changes.
Y
N
Check the wiring between
J8873
a loose or damaged connector. The wiring is good.
Y
N
Reconnect or repair as necessary.
Measure the voltage between
is approximately +5VDC.
Y
N
Install a new finisher PWB,
Measure the voltage between
the stacker height sensor 1. The voltage changes.
Y
N
Install a new stacker height sensor 1,
Install a new finisher
PWB,PL 13.45 Item
Enter
dC330
code 012-265. Actuate the stacker height sensor 2. The display changes.
Y
N
Check the wiring between
J8874
a loose or damaged connector. The wiring is good.
Y
N
Reconnect or repair as necessary.
Measure the voltage between
is approximately +5VDC.
Y
N
Install a new finisher PWB,
A
B
April 2017
2-84
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
WARNING
10. Disconnect the power cord. Electricity can cause
PL 13.27
actuators.
pin 2 and
P/J8988
pin 17 for an open or short circuit, or
P/J8988
pins 16 and 18 on the finisher PWB. The voltage
PL 13.45 Item
2.
P/J8988
pin 17 on the finisher PWB and ground. Actuate
PL 13.27 Item
16.
2.
pin 2 and
P/J8988
pin 20 for an open or short circuit, or
P/J8988
pins 19 and 21 on the finisher PWB. The voltage
PL 13.45 Item
2.