3-330 2nd DDI IISS Communication Failure RAP

3-330 Fault Code indicates that a communication failure between the IOT PWB and the
DDI IISS was detected.
Initial Actions
Refer to BSD 16.1, Printer IDFE, in this procedure.
Procedure
Perform the following:
PO/PO the machine
Go to BSD 16.1
(Figure
1) and check the communications cables.
Reset the IOT CPU connectors and reseat the IOT NVM PWB.
Reload IDFE System Software
Replace the IOT CPU PWB
(PL
9.2)
Replace the IDFE
(PL
19.1)
Reissue
DocuColor 12/DCCS50

3-333 Foreign Interface RAP

This Fault Code indicates that a communications failure was detected between the Foreign
Interface PWB and the IOT CPU PWB.
Initial Actions
Check the connection between the Foreign Interface PWB and the Foreign Accessory (P/
J 940).
If you were sent to this RAP from Call Flow for a nonrecognized Foreign Device, go to
Flag 1
on BSD 3.6 and check for an open circuit.
Use BSD 3.6, Foreign Interface Accessory, and BSD 3.12, Monitoring, for this procedure.
Procedure
PO/PO the machine. Fault Code 3-333 is still present.
Y
N
If intermittent performance is suspected, reseat
the Distribution PWB, and P/J 941at the FI PWB.
There is +24 VDC from J 941, pin 5 to pin 7.
Y
N
Go to
Flag 2
on BSD 3.6. Check for an open circuit. If the wires are OK, go to the 24 VDC
wirenets to troubleshoot.
There is +5 VDC from J 941, pin 10 to pin 8.
Y
N
Go to
Flag 3
on BSD 3.6. Check for an open circuit. If the wires are OK, go to the +5 VDC
wirenets to troubleshoot.
Perform the following:
Go to
Flag 4
and
Flag 5
on BSD 3.6, and check for an open/short circuit.
Replace the Foreign Interface PWB
Replace the IOT CPU PWB
(PL
1/05
3-330 2nd DDI IISS Communication Failure RAP, 3-
2-19
P/J406
at the IOT CPU PWB,
(PL
9.4).
9.2).
Status Indicator RAPs
P/J45
at