062-311 IIT/IPS Software RAP
BSD-ON: 6.2
A software error was detected by the IIT/IPS PWB.
Procedure
Perform
GP 8
Firmware version. The firmware is the latest version.
Y
N
Reload Software
(ADJ
9.3.1).
Replace the IIT/IPS PWB
(PL
11.3).
Launch Version
WorkCentre 5225, 5230
062-345 IIT/IPS Subsystem RAP
BSD-ON: 3.1
The IPS EEPROM failed during a read/write operation.
Procedure
Check the connection of each IIT/IPS PWB connector. The connectors are securely con-
nected.
Y
N
Connect the connectors.
Switch on the power. The problem persists.
Y
N
Return to Service Call Procedures.
Replace the IIT/IPS PWB
(PL
February, 2008
2-513
11.3).
062-311, 062-345