Advanced-control timers (TIM1&TIM8)
14
Advanced-control timers (TIM1&TIM8)
This section applies to the whole STM32F4xx family, unless otherwise specified.
14.1
TIM1&TIM8 introduction
The advanced-control timers (TIM1&TIM8) consist of a 16-bit auto-reload counter driven by
a programmable prescaler.
It may be used for a variety of purposes, including measuring the pulse lengths of input
signals (input capture) or generating output waveforms (output compare, PWM,
complementary PWM with dead-time insertion).
Pulse lengths and waveform periods can be modulated from a few microseconds to several
milliseconds using the timer prescaler and the RCC clock controller prescalers.
The advanced-control (TIM1&TIM8) and general-purpose (TIMx) timers are completely
independent, and do not share any resources. They can be synchronized together as
described in
14.2
TIM1&TIM8 main features
TIM1&TIM8 timer features include:
●
16-bit up, down, up/down auto-reload counter.
●
16-bit programmable prescaler allowing dividing (also "on the fly") the counter clock
frequency either by any factor between 1 and 65536.
●
Up to 4 independent channels for:
–
–
–
–
●
Complementary outputs with programmable dead-time
●
Synchronization circuit to control the timer with external signals and to interconnect
several timers together.
●
Repetition counter to update the timer registers only after a given number of cycles of
the counter.
●
Break input to put the timer's output signals in reset state or in a known state.
353/1422
Section
14.3.20.
Input Capture
Output Compare
PWM generation (Edge and Center-aligned Mode)
One-pulse mode output
Doc ID 018909 Rev 4
RM0090
Need help?