TIMED REMINDER

PROGRAMMING
To provide the internal music source on the MP card:
START
CM12
Assign the Service Restriction Class A for
Timed Reminder to required stations.
Allow Timed Reminder in the Service Re-
CM15
striction Class A assigned by CM12 Y=02.
Assign the access code for Timed Re-
CM20
minder set and cancel.
Designate the type of tone source to be
CM48
connected when answering a Timed Re-
minder call.
CM90
Assign the Timed Reminder feature ac-
cess key to a D
CM08
Specify the timing for Timed Reminder
Start.
CM41
Specify the duration of a Timed Reminder
call.
A
DESCRIPTION
INITIAL
term
, if required.
Y=02
(1)
X-XXXXXXXX: Station No.
(2)
XX ZZ
XX: 00-15 : Service Restriction Class
Y=13
(1)
00-15: Service Restriction Class A as-
(2)
1 : Allow
Y=0-3 Numbering Plan Group 0-3
(1)
X-XXXX: Access Code
(2)
A024: Set
A025: Cancel
Y=1
(1)
00: Tone source of Timed Reminder
(2)
1400: Hold Tone source on MP card
Y=00
(1)
My Line No. +
(2)
F0024
(1)
228: Timed Reminder Start timing
(2)
0 : At preset time
1 : Before 5 minutes of preset time
Y=0
(1)
23
(2)
01-08: 4 sec.-32 sec.
If no data is set, the default setting is 28-32
sec.
– 516 –
TIMED REMINDER
DATA
A
signed by CM12 Y=02
,
+ Key No.
(4 sec. increments)
A2512-10