AUTHORIZATION CODE

PROGRAMMING
There are two kinds of processor for Authorization Code. One is MP card, the other is AP01 card.
For MP card, EXPMEM card can be used to expand the number of codes.
(1) With MP card
START
Designate the processor for this feature as
CM08
MP card.
Specify whether Service Set Tone is pro-
vided after dialing the access code for Au-
thorization Code.
CM12
Assign the Service Restriction Class A for
Authorization Code to the required sta-
tions.
Allow Authorization Code in the Service
CM15
Restriction Class A assigned by CM12
Y=02.
Assign the access code for Authorization
CM20
Code.
CM42
Specify the maximum number of digits for
Authorization Code.
A
DESCRIPTION
(1)
216: Processor for Authorization Code
(2)
0: MP card
(1)
362: Service Set Tone after dialing the
access code
(2)
0 : No tone
1 : Service Set Tone
Y=02
(1)
X-XXXXXXXX: My Line No.
(2)
XX ZZ
XX: 00-15 : Service Restriction Class
Y=31 Authorization Code
(1)
00-15: Service Restriction Class A
assigned by CM12 Y=02
(2)
1 : Allow
Y=0-3 Numbering Plan Group 0-3
(1)
X-XXXX: Access Code
(2)
A086: Authorization Code
(1)
11
(2)
01-16
NONE : 16 digits
– 49 –
AUTHORIZATION CODE
DATA
A
: 1 digit-16 digits
A2042-10