NEC NEAX 2000 Programming Manual page 190

Integrated voice server, integrated multimedia exchange
Hide thumbs Also See for NEAX 2000:
Table of Contents

Advertisement

A
CME9
Assign a password to each Password Lev-
el.
Provide the system with Password Fea-
ture. After setting this data, access to sys-
tem programming will be available with
password entry only.
END
If the system data all clear is required before programming from a CAT, perform the
NOTE 1:
following operations.
1. Plug the DLC card into LT00 Slot of PIM0.
2. Connect the CAT to LEN000 at the MDF.
3. Set SW3 on the MP card to "B".
4. Press the SW1 on the MP card (System Data All Clear).
5. Set SW3 to "0" and press the SW1.
6. Set the D
term
D
.)
If Password Service is activated, do the following operation.
NOTE 2:
To log in the password mode and enter the password assigned by CME9 (To start the
work):
ST
+ DE
+
03
To log off the password mode (To finish the work):
ST
+
03
+ DE
HARDWARE REQUIRED
term
D
and DLC card
DESCRIPTION
term
to CAT mode. (Station number 300 is automatically assigned to the
+
Password Level No. (0-7)
CCCCCCCC
+
9
+
DE +
(8 digits)
CUSTOMER ADMINISTRATION TERMINAL (CAT)
(1)
0-7: Password Level 0-7
(2)
X-X...X: Max. 8 digits Password Code
A password code for Password Level 7
must be assigned prior to providing the
password service by Function No. 9 of
CME9.
The following passwords are not available.
"CCCCCCCC"
"FFFFFFFF"
(1)
9
(2)
0: Provided
Password
DE +
+
(Max. 8 digits)
+
EXE
– 170 –
DATA
EXE
+
A2168-10