A
CM35
B
DESCRIPTION
TOLL RESTRICTION-TOTAL DIGIT COUNT
Y=04 Answer Signal Condition
•
(1)
00-63: Trunk Route No.
(2)
0 : Answer Signal by Meter Pulse
1 : Answer Signal by Polarity Reversal
7 : No answer Signal
In case of no Answer Signal, system recog-
nizes the answer in timing set by CM41
Y=0>03.
Y=05 Release Signal Condition
•
(1)
00-63: Trunk Route No.
(2)
0 : No Release Signal from C.O.
1 : Release Signal from C.O.
Y=08 Dial Pulse Sending
•
(1)
00-63: Trunk Route No.
(2)
3 : To send
Y=09 Signaling
•
(1)
00-63: Trunk Route No.
(2)
15 : Ring Down/Loop Start
Y=13
•
Maximum number of sending digits
(1)
00-63: Trunk Route No.
(2)
001-254: Maximum number of sending
Y=39 Trunk Release by Reverse Signal
•
from C.O.
(1)
00-63: Trunk Route No.
(2)
0 : Not released
1 : To release
– 525 –
DATA
digits
A2523-10