DO NOT DISTURB

PROGRAMMING
To provide Do Not Disturb from a guest station or administrative station, or Front Desk Terminal,
or Hotel Console, or PMS:
START
CM12
Assign the Service Restriction Class A to
required stations.
Allow Do Not Disturb in the Service Re-
CM15
striction Class A assigned by CM12 Y=02.
Assign the access code for Do Not Disturb
CM20
Set/Cancel.
CM51
Assign the destination of a call transferred
when the called station is in Do Not Dis-
turb.
CM90
Assign the Call Forwarding-Intercept
(ICPT) key, if ATTCON/DESKCON is as-
signed as destination by CM51 Y=10.
Assign the DND function key to the D
if required.
A
DESCRIPTION
Y=02
(1)
X-XXXX: Station No.
(2)
XX ZZ
XX: 00-15 : Service Restriction Class
Y=19
(1)
00-15: Service Restriction Class A as-
(2)
1 : Allow
Y=0-3 Numbering Plan Group 0-3
(1)
X-XXXX: Access Code
(2)
A022: Set
A023: Cancel
Y=10
(1)
00-63: Tenant No.
(2)
X-XXXX: Station No.
or
E000: Attendant Console
Y=00
(1)
ATTCON No. (E000-E007) +
Key No.
(2)
F6065: Call Forwarding-Intercept
term
,
Y=00
(1)
My Line No. +
(2)
F0022: Do Not Disturb set/reset
– 657 –
DO NOT DISTURB
DATA
A
signed by CM12 Y=02
,
+ Key No.
,
+
A2653-10