Toll Denial/Toll Diversion - NEC NEAX 2000 Programming Manual

Integrated voice server, integrated multimedia exchange
Hide thumbs Also See for NEAX 2000:
Table of Contents

Advertisement

TOLL DENIAL/TOLL DIVERSION

PROGRAMMING
In addition to the system data programming of TOLL RESTRICTION-3/6-DIGIT
do the following programming.
START
Provide the system with the Toll Diversion
CM08
or the Toll Denial.
CM12
Assign a Trunk Restriction Class to each
station.
CM35
Specify the route access capability of each
Restriction Class.
See "RESTRICTION FROM OUTGOING
CALLS".
END
DESCRIPTION
page 414
TOLL DENIAL/TOLL DIVERSION
(1)
119
(2)
0 : Toll Diversion (Routed to "ICPT"
key on ATTCON.)
1 : Toll Denial
(Routed to Reorder Tone)
Y=01
(1)
X-XXXXXXXX: Station No.
(2)
X Z: Trunk Restriction Class
X: 1-8: In Day Mode
Z: 1-8: In Night Mode
Y=51-58
(1)
00-63: Trunk Route No.
(2)
0 : Restricted
1 : Allow
– 523 –