B
Specify whether no Dial Tone connection
CM48
is required for the answering method as-
signed by CM64 Y=0.
Specify the ringing cadence for an Auto-
CM08
mated Attendant call.
Specify the process when a call is trans-
ferred by an Automated Attendant to a pre-
determined station and time-out occurs.
Specify the process for an Automated At-
tendant call when a caller dials while re-
ceiving the message or music.
CM41
Specify the time before answering by Au-
tomated Attendant.
Specify the time before an Automated At-
tendant call is redirected because no digits
are received from the calling party.
Specify the timing of unanswered call after
forwarding to predetermined station in Au-
tomated Attendant.
Specify the time before Dial Tone timeout
in Automated Attendant.
END
DESCRIPTION
INITIAL
Y=2
•
(1)
06
(2)
0 : No DT
1 : DT
(1)
180
(2)
0 : As per CM08>392-Pattern 2
1 : As per CM35 Y=33
(1)
359
(2)
0 : Disconnect the call
1 : Continue to call
(1)
363
(2)
0 : Not allow (Allowed after receiving
the message or music)
1 : Allow
Y=0
•
(1)
59
(2)
00-08: 0 sec.-32 sec.
(4 sec. increments)
If no data is set, the default setting is 4-8
sec.
Y=0
•
(1)
34
(2)
01-30: 4 sec.-120 sec.
(4 sec. increments)
If no data is set, the default setting is 32-36
sec.
Y=0
•
(1)
39
(2)
01-30: 4 sec.-120 sec.
(4 sec. increments)
If no data is set, the default setting is 32-36
sec.
Y=0
•
(1)
43
(2)
01-14: 0 sec.-14 sec.
(1 sec. increments)
If no data is set, the default setting is 14
sec.
– 58 –
AUTOMATED ATTENDANT
DATA