To provide the Night Announcement by Digital Announcement Trunk:
START
CM10
Assign a Digital Announcement Trunk card
number to the required LEN.
The Digital Announcement Trunk
NOTE:
card number must be assigned
to the first LEN (Level 0), the
third LEN (Level 2), the fifth LEN
(Level 4) and the seventh LEN
(Level 6) of each LT slot.
Assign the Digital Announcement Trunk
CM30
number to each incoming trunk.
CM49
Assign the function of the Digital An-
nouncement Trunk to Night Announce-
ment.
CM41
Specify the duration of an Announcement.
To record, replay, or delete a message, as-
CM20
sign the respective Digital Announcement
Trunk access code.
END
DESCRIPTION
(1)
000-763: LEN
(2)
EB002-EB127: Digital Announcement
For PIM0/1: EB002-EB031
For PIM2/3: EB032-EB063
For PIM4/5: EB064-EB095
For PIM6/7: EB096-EB127
NOTE:
Y=03
(1)
000-255: Trunk No.
(2)
04: Direct-In Termination
Y=05
(1)
000-255: Trunk No.
(2)
EB000-EB127: Digital Announcement
Y=00
(1)
000-001: Built-in DAT on MP card
002-127: Digital Announcement Trunk
(2)
03000: Night Announcement Service
Y=0
(1)
45
(2)
01-30: 4 sec. -120 sec.
(4 sec. increments)
If no data is set, the default setting is 60-64
sec.
Y=0-3 Numbering Plan Group 0-3
(1)
X-XXXX: Access Code
(2)
A100: Record
A101: Replay
A102: Delete
– 30 –
ANNOUNCEMENT SERVICE
DATA
Trunk Card No.
EB000 and EB001 are dedi-
cated to built-in Digital An-
nouncement Trunk of the MP
card.
Trunk No. assigned by
CM10
Card No. (EB002-EB127) as-
signed by CM10
A2018-10