To provide the distinctive ringing patterns to D
tween an internal call from the main PBX and an external incoming call:
START
CM08
Specify the ringing pattern on an internal
call.
Specify interval of ringer until detecting a
ringing frequency from the Main PBX
(Centrex). Ringing is sent from D
detection of the ringing frequency.
Specify lamp indication of D
tecting the kind of incoming call from Main
PBX (Centrex).
The lamp is lit until detection of the ringing
frequency.
Specify ringing distinction by detecting the
ringing signal from the Main PBX (Centr-
ex).
When the ringer is for an internal
NOTE 1:
call, interval of ringing signal:
CM08>138
D
D
When the ringer is for an external
NOTE 2:
call, interval of ringing signal:
CM35 Y=33
D
D
A
DESCRIPTION
term
term
until de-
term
lamp color: Change to red
term
tone ringer: CM35 Y=34
term
lamp color: CM35 Y=32
term
tone ringer: CM35 Y=34
term
s in behind PBX, in order to distinguish be-
(1)
138: For Internal call
(2)
0 : As per CM08>392-Pattern 1
1 : As per CM08>396
(1)
380
(2)
0 : As per CM08>381
until
1 : As per CM35 Y=33
(1)
381
(2)
0 : No Ringer
1 : Ringing Tone (0.5 sec.) is sent
once
(1)
382
(2)
0 : Red Steady Light
1 : 120 IPM Flash
(As per CM35 Y=32)
(1)
366
(2)
0 : Longer Ringing than CM41
Y=2>40: External call
Shorter Ringing than CM41
Y=2>40: Internal call
1 : Longer Ringing than CM41
Y=2>40: Internal call
Shorter Ringing than CM41
Y=2>40: External call
– 237 –