TIE LINE ACCESS

PROGRAMMING
START
CM10
Assign a trunk number for the LDT/ODT
card to the required LEN.
The trunk number of LDT/ODT
NOTE:
card must be assigned to the first
LEN (Level 0) and the second
LEN (Level 1) of each LT slot.
Assign a Trunk Route access code to each
CM20
Tie Line Trunk route.
Assign a Trunk Route and Tenant number
CM30
to each Trunk.
CM35
Assign Trunk Route data to the Trunk
Route number.
A
DESCRIPTION
(1)
000-763: LEN
(2)
D000-D255: Trunk No.
Y=0-3 Numbering Plan Group 0-3
(1)
X-XXXX: Access Code
(2)
100-163: Trunk Route No. 00-63
Y=00
(1)
000-255: Trunk No.
(2)
00-63: Trunk Route No.
Y=01
(1)
000-255: Trunk No.
(2)
00-63: Trunk Route No.
Y=00
(1)
00-63: Trunk Route No.
(2)
04: Tie Line
Y=01
(1)
00-63: Trunk Route No.
(2)
< Incoming > < Outgoing >
2 : DP
4 : DTMF
7 : DTMF/DP
Y=02
(1)
00-63: Trunk Route No.
(2)
1 : Incoming Trunk
2 : Outgoing Trunk
3 : Bothway Trunk