NEC America, Inc. reserves the right to change the specifications, functions, or features, at any time, without notice. NEC America, Inc. has prepared this document for use by its employees and customers. The information contained herein is the property of NEC America, Inc. and shall not be reproduced without prior written approval from NEC America, Inc.
Page 3
ISSUE No. ISSUE No. PAGE No. PAGE No. ISSUE 1 ISSUE 2 ISSUE 3 ISSUE 4 DATE FEBRUARY, 2000 DATE DATE DATE ISSUE 5 ISSUE 6 ISSUE 7 ISSUE 8 DATE DATE DATE DATE NEAX2000 IVS Revision Sheet 1/2 Remote PIM System Manual ND-70917 (E)
Page 4
ISSUE No. ISSUE No. PAGE No. PAGE No. ISSUE 1 ISSUE 2 ISSUE 3 ISSUE 4 DATE FEBRUARY, 2000 DATE DATE DATE ISSUE 5 ISSUE 6 ISSUE 7 ISSUE 8 DATE DATE DATE DATE NEAX2000 IVS Revision Sheet 2/2 Remote PIM System Manual ND-70917 (E)
INTRODUCTION Purpose INTRODUCTION PURPOSE This manual explains the system outline and installation procedure for providing the Remote PIM to the NEAX2000 IVS USING THIS MANUAL This manual contains the following chapters: CHAPTER 1 GENERAL INFORMATION This chapter explains the outline of system configuration, required equipment, system capacity, system conditions, and time slot allocation.
INTRODUCTION Reference Manuals REFERENCE MANUALS Refer to the following manuals during installation: Installation Procedure Manual Provides the installation procedures for the PBX system. Command Manual Describes the Customer Administration Terminal (CAT) operation, command function, and setting data required for programming the PBX system. Office Data Programming Manual Contains the Customer Specification Sheets and Office Data Programming Sheets.
CHAPTER 1 GENERAL INFORMATION This chapter explains the outline of system configuration, required equipment, system capacity, system conditions, and time slot alloca- tion. NEAX2000 IVS Remote PIM System Manual Page 3 ND-70917 (E), Issue 1.0...
CHAPTER 1 GENERAL INFORMATION System Outline SYSTEM OUTLINE Remote PIMs can be installed separately at the distance in one building, or between the offices via the Public Switching Telephone Network (PSTN). The customers in the Remote Site can use the same service features as in the Main Site. Remote PIMs are connected to the Main Site by T1 (1.5 Mbps) / E1 (2 Mbps) digital interface.
CHAPTER 1 GENERAL INFORMATION PIM Configuration PIM CONFIGURATION One PIM can be installed respectively as a Remote Site. A maximum of three Remote Sites can be provided. The number of Remote Sites determines the number of PIMs in one system. Table 1-1 shows the available PIM configuration for the Remote PIM System.
CHAPTER 1 GENERAL INFORMATION System Configuration SYSTEM CONFIGURATION System Configuration for T1 Figure 1-2 shows the system configuration for T1. Figure 1-2 System Configuration for T1 Main Site Remote Site Remote PIM1 23 B Channel DAIB DAIA 1 Line/TRK (FP1) (FP1) 1 D Channel 24 B Channel...
CHAPTER 1 GENERAL INFORMATION System Configuration System Configuration for E1 Figure 1-3 shows the system configuration for E1. Figure 1-3 System Configuration for E1 Main Site Remote Site Remote PIM1 30 B Channel DAID 1 DAIE Line/TRK (FP1) (FP1) 1 D Channel 30 B Channel DAIF 1 DAIF 1...
CHAPTER 1 GENERAL INFORMATION Required Equipment REQUIRED EQUIPMENT Table 1-2 shows the required equipment for providing the Remote PIM System. Table 1-2 Required Equipmen t EQUIPMENT FUNCTIONAL FUNCTION NAME NAME PN-DAIA T1 Digital Trunk Interface (23B + D, 1.5 Mbps) Card for Remote PIM Accommodates 24-channel PCM digital lines, and provides Firmware Processor and BUS interface...
Page 17
CHAPTER 1 GENERAL INFORMATION Required Equipment Table 1-2 Required Equipment (Continued) EQUIPMENT FUNCTIONAL FUNCTION NAME NAME PN-CP15 Firmware Processor Card Provides Line/Trunk interface, Memory (RAM 768 KB), and inter-module BUS interface. BUS interface functions as a driver/receiver of various signals, adjusts gate delay timing and cable delay timing, monitors I/O BUS and PCM BUS.
CHAPTER 1 GENERAL INFORMATION System Capacity SYSTEM CAPACITY System Capacity for T1 Table 1-3 shows the system capacity for T1. Table 1-3 System Capacity for T1 CAPACITY DESCRIPTION REMARKS MAIN PIM REMOTE PIM DAIA card – DAIB card – DAIC card Line/Trunk Ports –...
CHAPTER 1 GENERAL INFORMATION System Capacity System Capacity for E1 Table 1-4 shows the system capacity for E1. Table 1-4 System Capacity for E1 CAPACITY DESCRIPTION REMARKS MAIN PIM REMOTE PIM DAID card – DAIE card – DAIF card Line/Trunk Ports –...
CHAPTER 1 GENERAL INFORMATION System Conditions SYSTEM CONDITIONS • Only one PIM configuration is available at the Remote Site. • Remote PIM can be installed at a maximum of 400 m (1312 ft.) distance from the Main Site. Using the Optical Interface card (PN-M10) or line extension equipment (Repeater, MUX, etc.), the distance can be extended.
CHAPTER 1 GENERAL INFORMATION Time Slot Allocation TIME SLOT ALLOCATION Time Slot Allocation for T1 One time slot out of the last 24 time slots provided by DAIA-DAIB connection is used for the con- trol signaling channel. Figure 1-4 shows the examples of time slot allocation when mounting 8- port cards to the PIM.
CHAPTER 1 GENERAL INFORMATION Time Slot Allocation Figure 1-4 Time Slot Allocation for T1 (2 of 2) When using 1 DAIA card, 1 DAIB card and 4 DAIC cards Remote PIM 00-23 24-47 48-63 Highway Channel • 23 Time Slots for Line/Trunks DAIC 0 DAIC 1 DAIB •...
CHAPTER 1 GENERAL INFORMATION Time Slot Allocation Time Slot Allocation for E1 One time slot out of the last 32 time slots provided by DAID-DAIE connection is used for the con- trol signaling channel. Figure 1-5 shows examples of time slot allocation when mounting 8-port cards to the PIM.
Page 24
This page is for your notes. NEAX2000 IVS Remote PIM System Manual Page 16 ND-70917 (E), Issue 1.0...
CHAPTER 2 INSTALLATION This chapter explains how to install the Remote PIM hardware. This chapter describes only the installation procedures required for the Re- mote PIM System. Refer to the Installation Procedure Manual for general installation procedures. NEAX2000 IVS Remote PIM System Manual Page 17 ND-70917 (E), Issue 1.0...
CHAPTER 2 INSTALLATION Precautions Figure 2-1 Static Electricity Guard (2 of 2) • WHEN MAKING A SWITCH SETTING ON A CIRCUIT CARD CIRCUIT CARD WEAR A WRIST STRAP AND PERFORM THE WORK ON A GROUNDED CONDUCTIVE WORK SURFACE. • WHEN CARRYING A CIRCUIT CARD CIRCUIT CONDUCTIVE CARD...
Page 28
CHAPTER 2 INSTALLATION Precautions CAUTION You must hold the edge of a circuit card when plugging or unplugging the circuit card. If you touch another area, you may be exposed to hazardous voltages. NEVER TOUCH THE COMPONENTS OR SOLDERED SURFACE WITH BARE HANDS.
CHAPTER 2 INSTALLATION Installation Procedure INSTALLATION PROCEDURE Install the Remote PIM System according to the following procedure. Installation Procedure for Main Site Figure 2-2 shows a flowchart of the installation procedure for the Main Site. Figure 2-2 Installation Procedure for Main Site START Mounting DAIA Card for T1 / Page...
CHAPTER 2 INSTALLATION Installation Procedure Installation Procedure for Remote Site Figure 2-3 shows a flowchart of the installation procedure for the Remote Site. Figure 2-3 Installation Procedure for Remote Site START Mounting DAIB Card for T1 / Page DAIE Card for E1 Mounting DAIC Card for T1 / Page DAIF Card for E1...
CHAPTER 2 INSTALLATION Installation for Main Site INSTALLATION FOR MAIN SITE Mounting DAIA Card for T1 / DAID Card for E1 ATTENTION Contents Static Sensitive Handling (1) Before mounting the DAIA/DAID card, set the MB switch to UP position, Precautions Required and set the other switches to appropriate position.
CHAPTER 2 INSTALLATION Installation for Main Site BUS Cable Connection (1) Cable Connection Between BUS Connector on the BWB and DAIA/DAID Card Connect the DAIA/DAID card to the BUS connector on the BWB by the RMT BUS CA-A, as shown in Figure 2-4.
CHAPTER 2 INSTALLATION Installation for Main Site Figure 2-4 BUS Cable Connection (2 of 2) (b) When mounting DAIA/DAID card on PIM2, PIM4 NOTE When Main PIM is 5 or 6 PIM configuration, the DAIA/DAID card must be mounted on PIM2 and/or PIM4, and connected as follows: BUS1B BUS1A RMT BUS CA-A...
CHAPTER 2 INSTALLATION Installation for Main Site (2) Cable Connection Between DAIA/DAID Cards If two or three DAIA/DAID cards are mounted on one PIM, connect between the PCM0 connector and PCM1 connector on the DAIA/DAID cards by 17-TW-0.3 CONN CA-A, as shown in Figure 2-5.
CHAPTER 2 INSTALLATION Installation for Main Site (3) Cable Connection Between DAIA/DAID Card and DAIC/DAIF Card Connect between the RBUS connector on the DAIC/DAIF card and the BUS connector on the DAIA/DAID card by 48-TW-0.2 CONN CA, as shown in Figure 2-6.
CHAPTER 2 INSTALLATION Installation for Remote Site INSTALLATION FOR REMOTE SITE Mounting DAIB Card for T1 / DAIE Card for E1 ATTENTION Contents Static Sensitive Handling (1) Before mounting the DAIB/DAIE card, set the MB switch to UP position, Precautions Required and set the other switches to appropriate position.
CHAPTER 2 INSTALLATION Installation for Remote Site BUS Cable Connection Connect between the BUS connector on the DAIB/DAIE card and the RBUS connector on the DAIC/DAIF card by the 48-TW-0.2 CONN CA, as shown in Figure 2-7. Figure 2-7 DAIB/DAIE Between DAIC/DAIF Cable Connection •...
CHAPTER 2 INSTALLATION Installation for Remote Site Mounting Line/Trunk Card for T1 (1) Mount line/trunk cards in the LT slots on the Remote PIM. (2) Connect the line cables by referring to Figure 2-8 Table 2-1. Figure 2-8 Mounting Location of Line/Trunk Card for T1 AC/DC Remote PIM LTC1...
CHAPTER 2 INSTALLATION Installation for Remote Site Figure 2-9 Location of Each LEN for T1 • When opposite DAIA card is set to FP No. 1: SLOT No. LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT09 LT10 LT11 NOTE 2 •...
CHAPTER 2 INSTALLATION Installation for Remote Site Figure 2-10 LTC Connector Pin Arrangement for T1 (1 of 2) When 8-port card When 4-port card is mounted is mounted LTC0 (FP1) (FP2) (FP3) (FP1) (FP2) (FP3) /400 /600 LEN 200 /400 /600 /601 /401...
CHAPTER 2 INSTALLATION Installation for Remote Site Figure 2-10 LTC Connector Pin Arrangement for T1 (2 of 2) When 8-port card When 4-port card is mounted is mounted LTC2 (FP1) (FP2) (FP3) (FP1) (FP2) (FP3) /448 /648 LEN 248 /448 /648 /649 /449...
CHAPTER 2 INSTALLATION Installation for Remote Site Mounting Line/Trunk Card for E1 (1) Mount line/trunk cards in the LT slots on the Remote PIM. (2) Connect the line cables by referring to Figure 2-11 Table 2-2. Figure 2-11 Mounting Location of Line/Trunk Card for E1 AC/DC Remote PIM LTC1...
CHAPTER 2 INSTALLATION Installation for Remote Site Figure 2-12 Location of Each LEN for E1 • When opposite DAID card is set to FP No. 1: SLOT No. LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT09 LT10 LT11 NOTE 2 •...
CHAPTER 2 INSTALLATION Installation for Remote Site Figure 2-13 LTC Connector Pin Arrangement for E1 (1 of 2) When 8-port card When 4-port card is mounted is mounted LTC0 (FP1) (FP2) (FP3) (FP1) (FP2) (FP3) /400 /600 LEN 200 /400 /600 /601 /401...
CHAPTER 2 INSTALLATION Installation for Remote Site Figure 2-13 LTC Connector Pin Arrangement for E1 (2 of 2) When 8-port card When 4-port card is mounted is mounted LTC2 (FP1) (FP2) (FP3) (FP1) (FP2) (FP3) /448 /648 LEN 248 /448 /648 /649 /449...
CHAPTER 2 INSTALLATION Installation for Remote Site Power Failure Transfer (AUC) The PN-AUC card can be used as the PFT card at the Remote Site. • Figure 2-14 shows an outline of a PFT (PN-AUC) connection. • Figure 2-15 shows the MDF cross connection for a PFT (PN-AUC). Figure 2-14 PFT Connection Outline (AUC) Remote PIM TO C.O.
CHAPTER 2 INSTALLATION Installation for Remote Site Figure 2-15 MDF Cross Connection for PFT (AUC) (1 of 2) REMOTE PIM LTC0 PN-4COT Ring C.O.R0 LEN000 (No. 0) C.O. LINE C.O.T0 Ring C.O.R1 LEN001 (No. 1) C.O.T1 C.O. LINE LT00 PN-AUC 4Q-TW-0.3 CONN CA Ring Sta.
CHAPTER 2 INSTALLATION Installation for Remote Site Power Failure Transfer (8PFT) The PZ-8PFTB card can be used as the PFT card at the Remote Site. • Figure 2-16 shows an outline of a PFT (PZ-8PFTB) connection. Figure 2-16 PFT Connection Outline (8PFT) PZ-8PFTB Remote PIM PN-8LC...
CHAPTER 2 INSTALLATION Installation for Remote Site • Install the PZ-8PFTB card to the PIM according to the following steps: (1) Mount the PZ-8PFTB card into the PFT slot of the PIM. (2) Connect the champ connectors of 25-pair cables to the PFT0 and PFT1 connectors on the PZ-8PFTB card as shown in Figure 2-27.
CHAPTER 2 INSTALLATION Installation for Remote Site (3) Connect the 25-pair cables on the MDF. • Figure 2-18 shows the PFT connector pin assignment for each PFT circuit number (No. 0-No. 7). Figure 2-18 PFT Connector Pin Assignment PFT0 PFT1 Sta.
CHAPTER 2 INSTALLATION Installation for Remote Site • Figure 2-19 shows an example of the MDF cross connection for the No. 0 circuit on the PFT (PZ-8PFTB). Figure 2-19 MDF Cross Connection for PFT (8PFT) (1 of 2) TO C.O. LINE Ring Ring TO STATION...
CHAPTER 2 INSTALLATION Connection Between Main Site and Remote Site CONNECTION BETWEEN MAIN SITE AND REMOTE SITE DAI Connection at Main Site (1) When using the LTC connector on the BWB Connect the cable to a CSU or directly to the Remote PIM via the MDF as shown in Figure 2-21.
CHAPTER 2 INSTALLATION Connection Between Main Site and Remote Site Figure 2-22 Example of DAI MDF Cross Connection via LTC Connector (Main Site) PIM 0 LTC3 PN-DAIA/DAID RECEIVE AP09 SEND LTC3 PN-DAIC/DAIF TO CSU/ REMOTE PIM RECEIVE AP10 SEND 2 LTC3 CONNECTOR 1 LTC3 CONNECTOR LTC (J) LTC (J)
CHAPTER 2 INSTALLATION Connection Between Main Site and Remote Site (2) When using the CN connector on the DAI Card Connect the cable to a CSU or directly to the Remote PIM via the CN connector on the DAIA/DAIC/DAID/DAIF card as shown in Figure 2-23.
CHAPTER 2 INSTALLATION Connection Between Main Site and Remote Site DAI Connection at Remote Site Connect the cable to a CSU or directly to the Main PIM via the CN connector on the DAIB/DAIC/ DAIE/DAIF card as shown in Figure 2-24.
CHAPTER 2 INSTALLATION Connection Between Main Site and Remote Site Optical Cable Connection When using an optical cable to establish the connection between the Main PIM and Remote PIM, connect each end of the cable to the CN1 connector of the M10 cards on both sites. Two DAI cards are connected to one M10 card, via MDF through LTC connector on the BWB or CN con- nector on the DAI card.
CHAPTER 2 INSTALLATION Connection Between Main Site and Remote Site Figure 2-26 Example of M10 MDF Cross Connection via LTC Connector (Main Site) (1 of 2) PIM 0 LTC3 PN-DAIA/DAID RECEIVE AP09 SEND LTC3 PN-DAIC/DAIF RECEIVE AP10 SEND LTC1 PN-M10 RECEIVE No.
CHAPTER 2 INSTALLATION Connection Between Main Site and Remote Site Figure 2-26 Example of M10 MDF Cross Connection via LTC Connector (Main Site) (2 of 2) 1 LTC3 CONNECTOR LTC (J) 2 LTC3 CONNECTOR LTC (J) 3 LTC1 CONNECTOR LTC (J) NEAX2000 IVS Remote PIM System Manual Page 53...
CHAPTER 2 INSTALLATION Connection Between Main Site and Remote Site Figure 2-27 Example of M10 MDF Cross Connection via CN Connector (Remote Site) (1 of 2) REMOTE PIM PN-DAIB/DAIE RECEIVE MP12 SEND PN-DAIC/DAIF RECEIVE AP10 SEND LTC1 PN-M10 RECEIVE No. 1 SEND LT05 RECEIVE...
CHAPTER 2 INSTALLATION MP Reset Figure 2-27 Example of M10 MDF Cross Connection via CN Connector (Remote Site) (2 of 2) 1 CN CONNECTOR 2 LTC1 CONNECTOR LTC (J) MP RESET After mounting all DAI cards/M10 cards and establishing the connection between the Main Site and the Remote Site, press SW1 switch on the MP card.
Page 64
This page is for your notes. NEAX2000 IVS Remote PIM System Manual Page 56 ND-70917 (E), Issue 1.0...
CHAPTER 3 TROUBLESHOOTING This chapter explains the method for fault diagnosis and troubleshoot- ing when maintenance personnel detects fault occurrences by lamp indication on DAIA/DAIB/DAIC/DAID/DAIE/DAIF and M10 cards. For other system faults, refer to the Maintenance Manual. NEAX2000 IVS Remote PIM System Manual Page 57 ND-70917 (E), Issue 1.0...
CHAPTER 3 TROUBLESHOOTING Table 3-1 shows contents of the faults and the remedial action on each lamp status. Table 3-1 Remedial Action on Each Lamp Status CARD NAME LAMP STATUS FAULT CONTENT REMEDIAL ACTION PN-DAIA RUN lamp is not Abnormal operation 1 Reset the MB switch.
Page 67
CHAPTER 3 TROUBLESHOOTING Table 3-1 Remedial Action on Each Lamp Status (Continued) CARD NAME LAMP STATUS FAULT CONTENT REMEDIAL ACTION PN-DAIB RUN lamp is not Abnormal operation 1 Reset the MB switch. (DAIB) flashing. of DAIB card (Down→Up→Down) 2 If the fault cannot be cleared, replace the card.
Page 68
CHAPTER 3 TROUBLESHOOTING Table 3-1 Remedial Action on Each Lamp Status (Continued) CARD NAME LAMP STATUS FAULT CONTENT REMEDIAL ACTION PN-DAIC RUN lamp is not Abnormal operation 1 Reset the MB switch. (DAIC) flashing. of DAIC card (Down→Up→Down) 2 If the fault cannot be cleared, replace the card.
Page 69
CHAPTER 3 TROUBLESHOOTING Table 3-1 Remedial Action on Each Lamp Status (Continued) CARD NAME LAMP STATUS FAULT CONTENT REMEDIAL ACTION PN-DAID RUN lamp is not Abnormal operation 1 Reset the MB switch. (DAID) flashing. of DAID card (Down→Up→Down) 2 Check the setting of SW1. 1: FP No.
Page 70
CHAPTER 3 TROUBLESHOOTING Table 3-1 Remedial Action on Each Lamp Status (Continued) CARD NAME LAMP STATUS FAULT CONTENT REMEDIAL ACTION PN-DAIE RUN lamp is not Abnormal operation 1 Reset the MB switch. (DAIE) flashing. of DAIE card (Down→Up→Down) 2 If the fault cannot be cleared, replace the card.
Page 71
CHAPTER 3 TROUBLESHOOTING Table 3-1 Remedial Action on Each Lamp Status (Continued) CARD NAME LAMP STATUS FAULT CONTENT REMEDIAL ACTION PN-DAIF RUN lamp is not Abnormal operation 1 Reset the MB switch. (DAIF) flashing. of DAIF card (Down→Up→Down) 2 If the fault cannot be cleared, replace the card.
Page 72
CHAPTER 3 TROUBLESHOOTING Table 3-1 Remedial Action on Each Lamp Status (Continued) CARD NAME LAMP STATUS FAULT CONTENT REMEDIAL ACTION PN-M10 (M10) CK0 lamp is not on. Cable connection 1 Check to see if the cable failure between Digi- between Digital Trunk Inter- tal Trunk Interface face and M10 is correctly and No.
CHAPTER 4 CIRCUIT CARD INFORMATION This chapter explains the mounting location, the meaning of lamp in- dications, and the method of switch settings of each circuit card for the Remote PIM. NEAX2000 IVS Remote PIM System Manual Page 65 ND-70917 (E), Issue 1.0...
CHAPTER 4 CIRCUIT CARD INFORMATION How to Read This Chapter HOW TO READ THIS CHAPTER This chapter explains each circuit card used in this system. Explanations are given in alphabeti- cal order of the circuit card names within each circuit card category (Control, Application Proces- sor, and Line/Trunk).
CHAPTER 4 CIRCUIT CARD INFORMATION Mounting Location of Circuit Card MOUNTING LOCATION OF CIRCUIT CARD This section explains the conditions for mounting circuit cards for the Remote PIM. Figure 4-1 shows circuit card mounting slots allocated in the PIM. Figure 4-1 Mounting Location of Circuit Card AC/DC LTC1 LTC3...
CHAPTER 4 CIRCUIT CARD INFORMATION List of Required Cards LIST OF REQUIRED CARDS Table 4-1 shows the required cards that are explained in this section. Table 4-1 List of Required Cards EXTRACTION/ INSERTION WITH LAMP SWITCH POWER ON NAME X: PROVIDED X: PROVIDED REFERENCE X: ALLOWED...
CHAPTER 4 CIRCUIT CARD INFORMATION PN-CP15 (FP) PN-CP15 (FP) Locations of Lamps, Switches, and Connectors SENSE Lamp Indications LAMP COLOR FUNCTION NAME Green Flashes at 120 IPM while the circuit card is operating normally NEAX2000 IVS Remote PIM System Manual Page 69 ND-70917 (E), Issue 1.0...
Page 78
CHAPTER 4 CIRCUIT CARD INFORMATION PN-CP15 (FP) Switch Settings SWITCH SETTING SWITCH NAME FUNCTION CHECK NUMBER POSITION SENSE For setting FP No. (Rotary SW) For mounting this card in PIM0 For mounting this card in PIM2 For mounting this card in PIM4 For mounting this card in PIM6 NOTE 1 Not used...
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIA (DAI) PN-DAIA (DAI) Location of Lamps, Switches, and Connectors SENSE LINK LOOP PCM1 PCM0 Lamp Indications LAMP COLOR FUNCTION NAME Green Flashes at 120 IPM while this card is operating normally LINK Green Remains lit when a link between this card and a distant office is normally connected Goes out after 15 seconds of link disconnection Remains lit when detecting PCM signal loss or Frame Alignment...
Page 80
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIA (DAI) Switch Settings SWITCH SETTING SWITCH NAME FUNCTION CHECK NUMBER POSITION SENSE FP (Firmware Processor) Number setting for the (Rotary SW) DAIA card By this setting, the system regards the DAIA card and the opposite DAIB card as one Firmware Pro- cessor NOTE 1 Not used...
Page 81
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIA (DAI) SWITCH SWITCH SETTING FUNCTION CHECK NAME NUMBER POSITION SW2 (DIP SW) Control channel signaling data transmission speed: 48 kbps Control channel signaling data 1 2 3 4 5 6 7 8 transmission speed: 64 kbps DTI frame configuration: 12-Multi Frame DTI frame configuration:...
Page 82
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIA (DAI) SWITCH SWITCH SETTING FUNCTION CHECK NAME NUMBER POSITION SW3 (DIP SW) Set the equalizer according to the cable length between the system 1 2 3 4 and the CSU. CABLE LENGTH 0 - 40 m (0 - 131.2 ft.) 40 - 80 m (131.2 - 262.5 ft.)
Page 83
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIA (DAI) NOTE 3: When the source clock signal is supplied via the line between the Main Site and the Remote Site, set the SW1-1 and SW1-2 as indicated in the following table. In this case, DAIA cards (DAIA0, DAIA1) must be mounted in PIM0.
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIB (DAI) PN-DAIB (DAI) Location of Lamps, Switches, and Connectors SENSE LINK LOOP Lamp Indications LAMP COLOR FUNCTION NAME Green Flashes at 120 IPM while this card is operating normally LINK Green Remains lit when a link between this card and a distant office is normally connected Goes out after 15 seconds of link disconnection Remains lit when detecting PCM signal loss or Frame Alignment...
Page 85
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIB (DAI) Switch Settings SWITCH SETTING SWITCH NAME FUNCTION CHECK NUMBER POSITION SENSE Always set to 0 (Rotary SW) Not used MB (Toggle SW) For make-busy For normal operation DOWN NOTE 1 Always set to OFF (Piano Key SW) Always set to OFF Always set to OFF...
Page 86
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIB (DAI) SWITCH SWITCH SETTING FUNCTION CHECK NAME NUMBER POSITION SW2 (DIP SW) Control channel signaling data transmission speed: 48 kbps Control channel signaling data 1 2 3 4 5 6 7 8 transmission speed: 64 kbps DTI frame configuration: 12-Multi Frame DTI frame configuration:...
Page 87
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIB (DAI) SWITCH SWITCH SETTING FUNCTION CHECK NAME NUMBER POSITION SW3 (DIP SW) Set the equalizer according to the cable length between the system 1 2 3 4 and the CSU. CABLE LENGTH 0 - 40 m (0 - 131.2 ft.) 40 - 80 m (131.2 - 262.5 ft.)
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIC (DAI) PN-DAIC (DAI) Location of Lamps, Switches, and Connectors LINK LOOP TBUS RBUS Lamp Indications LAMP COLOR FUNCTION NAME Green Flashes at 120 IPM while this card is operating normally LINK Green Remains lit when the following connections are normal: •...
Page 89
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIC (DAI) Switch Settings SWITCH SWITCH SETTING FUNCTION CHECK NAME NUMBER POSITION MB (Toggle SW) For make-busy For normal operation DOWN NOTE Always set to OFF (Piano Key SW) Always set to OFF Always set to OFF Always set to OFF SW2 (DIP SW) Not used...
Page 90
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIC (DAI) SWITCH SWITCH SETTING FUNCTION CHECK NAME NUMBER POSITION SW3 (DIP SW) Set the equalizer according to the cable length between the system and the CSU. 1 2 3 4 CABLE LENGTH 0 - 40 m (0 - 131.2 ft.) 40 - 80 m (131.2 - 262.5 ft.)
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAID (DAI) PN-DAID (DAI) Location of Lamps, Switches, and Connectors SENSE LINK LOOP PCM1 PCM0 Lamp Indications LAMP COLOR FUNCTION NAME Green Flashes at 120 IPM while this card is operating normally LINK Green Remains lit when a link between this card and a distant office is normally connected Goes out after 15 seconds of link disconnection Remains lit when receiving the alarm signal from a distant office...
Page 92
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAID (DAI) Switch Settings SWITCH SETTING SWITCH NAME FUNCTION CHECK NUMBER POSITION SENSE FP (Firmware Processor) Number setting for the (Rotary SW) DAID card By this setting, the system regards the DAID card and the opposite DAIE card as one Firmware Pro- cessor.
Page 93
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAID (DAI) SWITCH SETTING SWITCH NAME FUNCTION CHECK NUMBER POSITION SW2 (DIP SW) Control channel signaling data transmission speed: 48 kbps Control channel signaling data 1 2 3 4 5 6 7 8 transmission speed: 64 kbps CRC Synchronization Detection Timer is provided.
Page 94
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAID (DAI) SWITCH SWITCH SETTING FUNCTION CHECK NAME NUMBER POSITION SW2 (DIP SW) Setting of control signal time slot SWITCH NUMBER TIME SLOT NUMBER 1 2 3 4 5 6 7 8 TS10 TS11 TS12 TS13 TS14 TS15...
Page 95
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAID (DAI) SWITCH SWITCH SETTING FUNCTION CHECK NAME NUMBER POSITION SW3 (DIP SW) Always set to ON Always set to ON 1 2 3 4 Always set to ON Always set to OFF JPS (Jumper Pin) Balanced transmission: Right 120 ohms (for twisted-pair cable)
Page 96
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAID (DAI) NOTE 3: When the source clock signal is supplied via the line between the Main Site and the Remote Site, set the SW1-1 and SW1-2 as the following table. In this case, DAID cards (DAID0, DAID1) must be mounted in PIM0.
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIE (DAI) PN-DAIE (DAI) Location of Lamps, Switches, and Connectors SENSE LINK LOOP Lamp Indications LAMP COLOR FUNCTION NAME Green Flashes at 120 IPM while this card is operating normally LINK Green Remains lit when a link between this card and a distant office is normally connected Goes out after 15 seconds of link disconnection Remains lit when receiving the alarm signal from a distant office...
Page 98
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIE (DAI) Switch Settings SWITCH SETTING SWITCH NAME FUNCTION CHECK NUMBER POSITION SENSE Always set to 0 (Rotary SW) Not used MB (Toggle SW) For make-busy For normal operation DOWN NOTE 1 Always set to OFF (Piano Key SW) Always set to OFF Always set to OFF...
Page 99
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIE (DAI) SWITCH SETTING SWITCH NAME FUNCTION CHECK NUMBER POSITION SW2 (DIP SW) Setting of control signal time slot SWITCH NUMBER TIME SLOT NUMBER 1 2 3 4 5 6 7 8 TS10 TS11 TS12 TS13 TS14 TS15...
Page 100
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIE (DAI) SWITCH SETTING SWITCH NAME FUNCTION CHECK NUMBER POSITION SW3 (DIP SW) Always set to ON 1 2 3 4 Always set to ON Always set to ON Always set to OFF JPS (Jumper Pin) Balanced transmission: Right 120 ohms (for twisted-pair cable)
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIF (DAI) PN-DAIF (DAI) Location of Lamps, Switches, and Connectors LINK LOOP TBUS RBUS Lamp Indications LAMP COLOR FUNCTION NAME Green Flashes at 120 IPM while this card is operating normally LINK Green Remains lit when the following connections are normal: •...
Page 102
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIF (DAI) Switch Settings SWITCH SWITCH SETTING FUNCTION CHECK NAME NUMBER POSITION MB (Toggle SW) For make-busy For normal operation DOWN NOTE Always set to OFF (Piano Key SW) Line impedance: 75 ohms (for coaxial cable) Line impedance: 120 ohms (for twisted-pair cable) Always set to OFF...
Page 103
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIF (DAI) SWITCH SWITCH SETTING FUNCTION CHECK NAME NUMBER POSITION SW2 (DIP SW) Control channel signaling data transmission speed: 48 kbps 1 2 3 4 5 6 7 8 Control channel signaling data transmission speed: 64 kbps CRC Synchronization Detection Timer is provided.
Page 104
CHAPTER 4 CIRCUIT CARD INFORMATION PN-DAIF (DAI) SWITCH SWITCH SETTING FUNCTION CHECK NAME NUMBER POSITION SW3 (DIP SW) Always set to ON Always set to ON 1 2 3 4 Always set to ON When mounting this card on Remote Site. When mounting this card on Main Site JPS (Jumper Pin)
CHAPTER 4 CIRCUIT CARD INFORMATION PN-M10 (M10) PN-M10 (M10) Location of Lamps, Switches, and Connectors TALM RALM CN1 TO OPTICAL CABLE Lamp Indications LAMP COLOR FUNCTION NAME Green Remains lit when a Digital Trunk Interface is connected to No. 0 circuit on this card Green Remains lit when a Digital Trunk Interface is connected to No.
Page 106
CHAPTER 4 CIRCUIT CARD INFORMATION PN-M10 (M10) Switch Settings SWITCH SETTING SWITCH NAME FUNCTION CHECK NUMBER POSITION JP0, 1 When connected to E1 (2 M) Digital (Jumper Pin) Trunk Interface When connected to T1 (1.5 M) DOWN Digital Trunk Interface JP2 (Jumper Pin) Line code: B8ZS* is provided.