HOUSE PHONE

PROGRAMMING
START
CM12
Assign House Phone Group number to re-
quired stations.
NOTE:
There is no limit to the number of
House Phone permitted in the
system as long as the maximum
number of ports is not exceeded.
CM51
Assign the destination of each House
Phone Group.
Specify the result of Switch Hook Flash on
CM08
stations within each House Phone Group.
To allow stations within a House Phone
Group to transfer a call or access a fea-
ture, set the data to "0".
END
DESCRIPTION
Y=03
(1)
X-XXXXXXXX: Station No.
(2)
00-03: House Phone Group 0-3
Y=14
(1)
00-03: House Phone Group 0-3
(2)
X-XXXXXXXX: Station No. of the desti-
E000: Attendant Console
For assigning the Attendant Console as
destination, set "E000" to each House
Phone Group.
(1)
055: For House Phone Group 0, 1
056: For House Phone Group 2, 3
(2)
0 : Special Dial Tone
1 : Attendant Recall
– 273 –
HOUSE PHONE
DATA
nation
A2270-10