CALL PARK-SYSTEM

PROGRAMMING
START
CM08
Specify whether a trunk placed on consul-
tation hold by Call Park-System can be re-
trieved by pressing a trunk line
appearance key on a D
CM12
Assign Service Restriction Class C to
each station.
Assign type of D
CM15
Class C assigned by CM12 Y=07.
Assign an access code for Call Park-Sys-
CM20
tem set and retrieve.
CM41
Specify the recall timing for the Call Park-
System.
Assign a Call Park-System function key to
CM90
term
the D
, if required.
Assign a Call Park-System function key to
ATTCON/DESKCON, if required.
END
HARDWARE REQUIRED
term
D
and DLC card as required
DESCRIPTION
term
.
term
to Service Restriction
(1)
133
(2)
0 : Not available
1 : Available
Y=07
(1)
X-XXXXXXXX: Station No.
(2)
00-15 : Service Restriction Class C
Y=96
(1)
00-15: Service Restriction Class C
(2)
1
: With LCD
Y=0-3 Numbering Plan Group 0-3
(1)
X-XXXX: Access Code
(2)
A008: Call Park-System Set
A009: Call Park-System Retrieve
Y=0
(1)
05
(2)
01-98: 4 sec.-392 sec.
99
: Recall is not performed
If no data is set, the default setting is 60-64
sec.
Y=00
(1)
My Line No. +
(2)
F5000
Y=00
(1)
ATTCON No. (E000-E007) +
No.
(2)
F6144: Call Park key
– 132 –
CALL PARK-SYSTEM
DATA
assigned by CM12 Y=07
(4 sec. increments)
,
+ Key No.
,
+ Key
A2131-10