STEP 12 Set the MB switch to ON (UP) on the third CIR trunk with AP number Z.
STEP 13 As for the fourth CIR trunk, change the AP number W to X by CM05 and by the SENSE
switch.
STEP 14 Set the SW1-1 through SW1-4 to ON on the fourth CIR trunk.
Clear the memory for CMDC and CMDB by CMDB Y=90.
Set the SW1-1 through SW1-4 to OFF on the fourth CIR trunk.
STEP 15 Load the office data saved in STEP1 by MAT.
STEP 16 As for the fourth CIR trunk, restore the AP number X to W by CM05 and by the SENSE
switch.
STEP 17 Set the MB switches to OFF (DOWN) on all the CIR trunks.
HARDWARE REQUIRED
COT card (4COTG/8COTQ)
CIR card (4RSTC)
term
D
with LCD and DLC card
FEATURES FOR OTHER COUNTRIES ONLY
– 602 –