A
For example, to provide the system with
the following numbering plan:
200-299
2100-2199 (4 digits Station Numbers)
2200-2299 (4 digits Station Numbers)
Assign the digit "2" to data 824 (2-4 digits
Station No.) and then assign the station
numbers to each LEN by CM10. For call-
ing the station 200-299, press "#" key or
wait for ring start after dialing the station
number.
Specify the inter-digit timer for Timing
CM41
Start.
END
DESCRIPTION
(3 digits Station Numbers)
SINGLE DIGIT STATION CALLING WITH TIMING
Y=0
(1)
13
(2)
03-08: 3 sec.-8 sec.
If no data is set, the default setting is 4-5
sec.