NEC NEAX 2000 Programming Manual page 231

Integrated voice server, integrated multimedia exchange
Hide thumbs Also See for NEAX 2000:
Table of Contents

Advertisement

D
CM41
Specify the various timing, if required.
CM20
Assign an access code for the DTI trunk
route.
The Least Cost Routing or Route Advance feature is available for call origination
NOTE:
via the DTI.
Refer to the following feature programming.
LEAST COST ROUTING-3/6 DIGIT
LEAST COST ROUTING-TIME OF DAY ROUTING
ROUTE ADVANCE
END
DESCRIPTION
page 420
DIRECT DIGITAL INTERFACE (DDI)
Y=3
(1)
00: Release Signal Detect Timing
(2)
01-15: 64 ms.-960 ms.
If no data is set, the default setting is 128
ms.
Y=3
(1)
01: Answer Signal Detect Timing
(2)
01-15: 32 ms.-480 ms.
If no data is set, the default setting is 128
ms.
Y=3
(1)
02: Wink Signal width
(2)
01-15: 64 ms.-512 ms.
If no data is set, the default setting is 32 ms.
Y=3
(1)
03: Wink/Delay Detection Timeout
(2)
01-15: 1 sec.-15 sec.
If no data is set, the default setting is 7 sec.
Y=0-3 Numbering Plan Group 0-3
(1)
X-XXXX: Access Code
(2)
100-163: Trunk Route No. 00-63
page 286
– 211 –
PROGRAMMING
24-DTI Assignment
DATA
(64 ms. increments)
(32 ms. increments)
(32 ms. increments)
(1 sec. increments)
page 298
A2195-10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Neax 7400 ics m100mx

Table of Contents