NEC NEAX 2000 Programming Manual page 132

Integrated voice server, integrated multimedia exchange
Hide thumbs Also See for NEAX 2000:
Table of Contents

Advertisement

B
CM42
Specify the measured rate, if franc/cen-
time required.
Use first data: 69 for dollar/franc, and use
first data: 70 for cent/centime.
By this setting, the call charge is calculat-
ed according to the message rate sent
from the network, and is sent to the D
TIMS printer.
CMD000
Specify the Printer Line Feed Code.
Assign the attribute data, depending on
CMD001
the channel (Port 1 or 3) connected to the
printer.
FIRST DATA (1)
PORT
PORT
0
1
24
25
26
27
100
102
103
104
C
DESCRIPTION
AP00 INITIAL
PORT
PORT
2
3
32
Data Speed
33
Stop Bit
34
Data Length
35
Parity
140
Equipment Type
No. of characters per
142
line to be printed out
143
No. of lines per page
No. of lines per page
to be printed out
144
CALL INFORMATION SYSTEM (CIS)
(1)
69: dollar/franc
(2)
00-99: 00-99 dollars/franc
(1)
70: cent/centime
(2)
00-99: 00-99 cents/centimes
term
(1)
103
(2)
0 : CR
1 : CR + LF
(1)
See the following table.
(2)
See the following table.
SECOND
MEANING
DATA (2)
2/3/4
2
0
1
16/17
2
0-88
0-88
– 112 –
PROGRAMMING
term
D
TIMS Programming
DATA
MEANING
1200/2400/4800 bps
2 bits
7 bits
Even Parity
Printer 0/Printer 1
80 characters
0 : No page
1 : No. of lines
including space
within a page
(Depends on size
88: of printer paper
used)
0 : No page
1 : No. of lines to be
printed out within
88: a page
A2107-10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Neax 7400 ics m100mx

Table of Contents