Call Forwarding-Busy Line; Call Forwarding-Busy Line-D Term; Call Forwarding-Busy Line-Outside - NEC NEAX 2000 Programming Manual

Integrated voice server, integrated multimedia exchange
Hide thumbs Also See for NEAX 2000:
Table of Contents

Advertisement

CALL FORWARDING-BUSY LINE

CALL FORWARDING-BUSY LINE-D

CALL FORWARDING-BUSY LINE-OUTSIDE

PROGRAMMING
START
CM12
Assign the Service Restriction Class A for
this feature to the required stations.
Allow Call Forwarding-Busy Line in the
CM15
Service Restriction Class A assigned by
CM12 Y=02.
When providing Call Forwarding-
NOTE:
Busy Line-Outside, set "1" (Al-
low) for CM15 Y=11, Y=28, Y=12,
Y=29.
Assign the access code for Call Forward-
CM20
ing-Busy Line.
A
DESCRIPTION
CALL FORWARDING-BUSY LINE
CALL FORWARDING-BUSY LINE-D
CALL FORWARDING-BUSY LINE-OUTSIDE
term
Y=02
(1)
X-XXXXXXXX: My Line No.
(2)
XX ZZ
XX: 00-15 : Service Restriction Class
Y=11 Call Forwarding-Busy Line
Y=28 Call Forwarding-Busy Line-Out-
side
Y=12 Call Forwarding-Busy Line/-Don't
Answer
Y=29 Call Forwarding- Busy Line-Out-
side/-Don't Answer-Outside
(1)
00-15: Service Restriction Class A as-
signed by CM12 Y=02
(2)
1 : Allow
Y=0-3 Numbering Plan Group 0-3
(1)
X-XXXX: Access Code
(2)
A014: Set
A015: Cancel
For setting the same access code as Call
Forwarding-Don't Answer
(2) A012: Set
A013: Cancel
– 85 –
DATA
A
A2076-10
term

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Neax 7400 ics m100mx

Table of Contents