Message Waiting - NEC NEAX 2000 Programming Manual

Integrated voice server, integrated multimedia exchange
Hide thumbs Also See for NEAX 2000:
Table of Contents

Advertisement

MESSAGE WAITING

PROGRAMMING
To provide the Message Waiting from an administrative station, Front Desk Terminal, Hotel Con-
sole, or PMS:
START
CM12
Assign the Service Restriction Class A for
Message Waiting to required guest or ad-
ministrative station as shown below.
Allow Message Waiting in the Service Re-
CM15
striction Class A assigned by CM12 Y=02.
GUEST/ADMINISTRATIVE
Guest station w/o MW
Lamp
Guest station with MW
Lamp
Administrative station
CM13
Provide each station with Message Wait-
ing Service (D
phone with Message Waiting Lamp).
Specify guest station or administrative
station to each station.
CM13 Y=13 data assignment is
NOTE:
not required when Message
Waiting is set by PMS.
Assign access code for Message Waiting
CM20
Set/Reset/Retrieve from administrative
station, if required.
CM20 Y=0-3 data assignment is
NOTE:
not required when Message
Waiting is set by PMS.
A
DESCRIPTION
CM15
CM15
Y=24
Y=40
0
0
1
term
or Single Line Tele-
Y=02
(1)
X-XXXX: Station No.
(2)
XX ZZ
XX: 00-15 : Service Restriction Class
Y=24 Administrative station allowing
Message Waiting set/reset to
guest room
Y=40 Guest Station
(1)
00-15: Service Restriction Class A as-
(2)
0 : Restricted
0
1 : Allow
1
0
Y=03
(1)
X-XXXX: Station No.
(2)
0: To provide
Y=13
(1)
X-XXXX: Station No.
(2)
0 : Administrative station
1 : Guest station
Y=0-3 Numbering Plan Group 0-3
(1)
X-XXXX: Access Code
(2)
A040: MW Lamp Control-Set
A041: MW Lamp Control-Reset
A147: MW Retrieve
– 679 –
MESSAGE WAITING
DATA
A
signed by CM12 Y=02
A2679-10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Neax 7400 ics m100mx

Table of Contents