NEC NEAX 2000 Programming Manual page 528

Integrated voice server, integrated multimedia exchange
Hide thumbs Also See for NEAX 2000:
Table of Contents

Advertisement

A
CM35
Assign the appropriate data for the char-
acteristic of distant PBX.
This data should be set to each
NOTE:
route according to the data for
CM35 Y=09, as shown below.
Data for CM35 Y=09 Data for CM35 Y=20
03
04
05
B
06
DESCRIPTION
00
01
15
15
Y=04
Answer Signal from distant office
(1)
00-63: Trunk Route No.
(2)
2 : Arrive
7 : No Signal
Y=05
Release Signal from distant office
(1)
00-63: Trunk Route No.
(2)
1 : Arrive
Y=08 Sending of Dial Pulse
(1)
00-63: Trunk Route No.
(2)
3
: Send
Y=09 Terminating System
(1)
00-63: Trunk Route No.
(2)
03: Wink Start
04: Delay Dial
05: Immediate Start
06: 2nd Dial Tone/Timing Start
Y=10 2nd DT sending on call termina-
tion
(1)
00-63: Trunk Route No.
(2)
0 : No Tone
1 : 2nd Dial Tone
Y=13 Maximum Number of Sending
Digits
(1)
00-63: Trunk Route No.
(2)
001-254: 1 digit-254 digits
If no data is set, sender is released when
timed out or called station answer.
Y=20 Sender Start Condition
(1)
00-63: Trunk Route No.
(2)
00 : Wink Start
01 : Delay Dial
15 : Timing Start
(Prepause per CM35 Y=21)
– 508 –
TIE LINE ACCESS
DATA
A2499-10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Neax 7400 ics m100mx

Table of Contents