Multi-Function Key-Attendant - NEC NEAX 2000 Programming Manual

Integrated voice server, integrated multimedia exchange
Hide thumbs Also See for NEAX 2000:
Table of Contents

Advertisement

MULTI-FUNCTION KEY-ATTENDANT

PROGRAMMING
START
CM60
Provide each ATTCON/DESKCON Multi-
Function key capability.
Assign the required Multi-Function keys to
CM90
each ATTCON/DESKCON.
The following data is assigned as
NOTE 1:
initial data or resident data.
Key No.
ATTCON
Status No.
00
F6110
(MODE)
01
F6112
(SPB)
02
03
04
F6110
(RC)
When setting or canceling a
NOTE 2:
group of stations in Do Not Dis-
turb/Room Cut Off, ATTCON
Status number 00 should be
used.
NOTE 3:
For the SN716 DESKCON Multi-
Function key, do not assign the
MODE key (F6110).
Key No. 05-06 is not available for
NOTE 4:
SN716 DESKCON.
END
DESCRIPTION
01
02
03
04
05
F6111
(PROG)
F6113
F6106
F6105
(LPB)
(SHF)
(SC)
F6101
F6102
F6109
(MW)
(DD)
(WU)
MULTI-FUNCTION KEY-ATTENDANT
Y=17
(1)
0-7: ATTCON No. assigned by CM10
(2)
1 : Effective
Y=00
(1)
EXX Y +
(01-06: ATTCON, 01-04: DESKCON)
XX: 00-04: ATTCON Status No.
00: Idle State
01: When answering or originating
02: When called station is busy
06
03: When called station is in DND
04: When accessing Hotel feature
Y: 0-7: ATTCON No.
(2)
F6100: Room Cut Off
F6203
F6101: Message Waiting
(TALK)
F6102: Do Not Disturb
F6107
(BV)
F6104: Reset
F6105: Serial Call Set
F6108
(DDOV)
F6106: Flash over trunk
F6104
F6107: Busy Verification
(RESET)
F6108: Do Not Disturb Override
F6109: Wake Up
F6110: Mode
F6111: Programming
F6112: Out pulse (PB Signal) Short
F6113: Out pulse (PB Signal) Long
F6203: Talk
– 339 –
DATA
,
+ Multi-Function key No.
NOTE 2
NOTE 3
A2337-10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Neax 7400 ics m100mx

Table of Contents