To provide Consecutive Speed Calling-System:
START
Assign Service Restriction Class A to
CM12
each station.
Allow Speed Calling-System in the Ser-
CM15
vice Restriction Class A assigned by
CM12 Y=02.
CM20
Assign the access code for Speed Calling-
System.
CM71
Assign the memory area for the Speed
Calling-System.
300 memory slot are available per system.
The number of slots available for each
Tenant is also 300.
Abbreviated Call Codes required for ac-
cessing this feature are automatically giv-
en to each Tenant shown below.
Example:
20
memory
slots
The number of digits for Abbreviated Code is automatically determined as shown below:
• Less than 100 memory slots per Tenant: 2 digits (00-99)
• In excess of 100 memory slots per Tenant: 3 digits (000-299)
A
DESCRIPTION
Tenant 00
Slot 000
00
Abbreviated
Codes
Slot 019
19
CONSECUTIVE SPEED CALLING
Y=02
(1)
X-XXXXXXXX: Station No.
(2)
XX ZZ
XX: 00-15 : Service Restriction Class
Y=06 Speed Calling-System
(1)
00-15: Service Restriction Class A as-
(2)
1 : Allow
Y=0-3 Numbering Plan Group 0-3
(1)
X-XXXX: Access Code
(2)
A067: Speed Calling-System
(1)
00-63: For stations within Tenant 00-63
64
: For Attendant Console
(2)
XXX YYY
XXX: 000-299: First Memory Slot No. in
YYY: 001-300: Number of Slots to be
For example, to provide 20 memory
slots starting at Slot 60:
Data=060020
Tenant 01
Slot 020
15
memory
slots
Slot 034
– 166 –
DATA
A
signed by CM12 Y=02
Block.
allocated in Block.
00
Abbreviated
Codes
14
A2157-10