Relay Control Function Key-D Term - NEC NEAX 2000 Programming Manual

Integrated voice server, integrated multimedia exchange
Hide thumbs Also See for NEAX 2000:
Table of Contents

Advertisement

RELAY CONTROL FUNCTION KEY-D
PROGRAMMING
START
CM10
Assign the DK card to the required LEN.
The DK Card number must be
NOTE 1:
assigned to the first LEN (Level
0) and the third LEN (Level 2) of
each LT.
CM44
Assign the function of relay control via
term
D
to the DK.
Assign the Relay Control (ON/OFF) key on
CM90
the required D
END
HARDWARE REQUIRED
DK card or MP card (built-in DK)
External equipment provided locally
term
D
and DLC card
DESCRIPTION
term
.
– 403 –
RELAY CONTROL FUNCTION KEY-D
term
DATA
(1)
000-763: LEN
(2)
E800-E831: DK Card No.
For PIM0/1: E800-E807
For PIM2/3: E808-E815
For PIM4/5: E816-E823
For PIM6/7: E824-E831
Circuit No. 3 of E831 is used
NOTE 2:
for built-in External Equip-
ment Interface of MP card by
setting CM44.
(1)
XX Y
XX : 00-31: DK Card No. assigned by
CM10
Y : 0-3: Circuit No.
313: MP Built-in External Equipment
Interface
(2)
1500: Relay Control (ON/OFF) Func-
tion Key via D
Y=00
,
(1)
My Line No. +
+ Key No.
(2)
F7 XX Z
XX: 00-31: DK Card No. assigned by
CM44
Z : 0-3: Circuit No. assigned by CM44
term
term
A2397-10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Neax 7400 ics m100mx

Table of Contents