DIRECT-IN TERMINATION (DIT)

PROGRAMMING
START
CM30
Assign the data for terminating system in
Day Mode/Night Mode/Mode A/Mode B of
the trunk respectively.
Assign the station number to be terminat-
ed by DIT in Day Mode/Night Mode/Mode
A/Mode B respectively.
Assign the transfer destination when the
DIT Station is busy/not available in the Day
Mode and Night Mode, respectively.
Assign the transfer destination for an un-
answered DIT Call in Day Mode and Night
Mode, respectively.
A
DESCRIPTION
DIRECT-IN TERMINATION (DIT)
Y=02 Day Mode
Y=03 Night Mode
Y=40 Mode A
Y=41 Mode B
(1)
000-255: Trunk No.
(2)
04: Direct-In Termination
Y=04 Day Mode
Y=05 Night Mode
Y=42 Mode A
Y=43 Mode B
(1)
000-255: Trunk No.
(2)
X-XXXXXXXX: Station No.
Y=13 Day Mode
Y=14 Night Mode
(1)
000-255: Trunk No.
(2)
01 : TAS BUZZER
04 : Attendant Console
06 : Automatic Camp-On
15 : Waiting until the DIT station be-
comes idle
Y=15 Day Mode
Y=16 Night Mode
(1)
000-255: Trunk No.
(2)
01 : Attendant Console
03 : TAS
15 : Keep the call ringing
– 232 –