NEC NEAX 2000 Programming Manual page 428

Integrated voice server, integrated multimedia exchange
Hide thumbs Also See for NEAX 2000:
Table of Contents

Advertisement

(2) With AP01 card
START
CM05
Assign the AP number to the AP01 card.
The AP number must match the
NOTE:
SENSE switch setting on the
AP01 card.
CM08
Designate the processor checking the ID
code for Remote Access to System as
AP01 card.
Assign the ring cadence on a Remote Ac-
cess to System call.
Assign the terminating system in Day
CM30
Mode, Night Mode, Mode A and Mode B
for incoming C.O. Calls to required trunks.
Specify the handling of busy/not available
Remote Access to System destination in
Day or Night Mode when calling an inter-
nal station.
A
DESCRIPTION
INITIAL
REMOTE ACCESS TO SYSTEM
Y=0
(1)
04-15: AP No.
(2)
07
(1)
217
(2)
1 : AP01 card
(1)
180
(2)
0 : As per CM08>392
1 : As per CM35 Y=33
Y=02 Day Mode
Y=03 Night Mode
Y=40 Mode A
Y=41 Mode B
(1)
000-255: Trunk No.
(2)
16: Remote Access to System
Y=30 Handling of busy/not available
Remote Access to System desti-
nation in Day Mode
Y=31 Handling of busy/not available
Remote Access to System desti-
nation in Night Mode
(1)
000-255: Trunk No.
(2)
00 : C.O. Line release
01 : Forwarded to TAS
03 : Forwarded to Attendant Console
04 : Forwarded to DIT station
assigned by CM30 Y=04, 05
06 : DT connection for redial
08 : C.O. line release
15 : C.O. line release
– 408 –
DATA
A2397-10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Neax 7400 ics m100mx

Table of Contents