OVERFLOW-UCD

PROGRAMMING
In addition to the programming of "UNIFORM CALL DISTRIBUTION (UCD)"
"CALL FORWARDING- BUSY LINE"
To provide an External Indicator for Overflowed UCD Call:
START
CM10
Assign the DK card to the required LEN.
The DK card number must be as-
NOTE:
signed to the first LEN (Level 0)
and third LEN (Level 2) of each
LT slot.
Assign the function of UCD Overflow Indi-
CM44
cation to the DK card.
Specify the UCD Overflow Indicator indi-
CM59
cation pattern.
END
page 85
DESCRIPTION
, do the following programming.
(1)
000-763: LEN
(2)
E800-E831: DK Card No.
For PIM0/1: E800-E807
For PIM2/3: E808-E815
For PIM4/5: E816-E823
For PIM6/7: E824-E831
NOTE:
(1)
XX Y
XX: 00-31: DK Card No. E800-E831
Y : 0-3: Circuit No.
313: MP built-in External Equipment In-
terface
(2)
14XX
XX: 00-15: UCD Group No. assigned
(1)
00
(2)
01: 30 IPM (1 sec. ON/OFF)
02: 60 IPM (0.5 sec. ON/OFF)
03: 120 IPM (0.25 sec. ON/OFF)
07: Steadily On
NONE : 120 IPM (0.25 sec. ON/OFF)
– 367 –
OVERFLOW-UCD
page 546
DATA
Circuit No. 3 of E831 is used
for built-in External Equip-
ment Interface on MP card by
setting CM44.
assigned by CM10
by CM17
and