D
STEP 3: Assign the starting time for the
CM8A
Toll Restriction and Route Pat-
tern number to the Time Pattern
number assigned by Step 2.
Set the starting time as shown
below.
NOTE:
Two times must be set, the first to
start Toll Restriction and the sec-
ond to stop it (or change it back).
STEP 4: Assign the TR Pattern number to
the Route Pattern number as-
signed by Step 3.
STEP 5: Assign the Trunk Restriction Pat-
tern number assigned by CM81
to the TR Pattern number as-
signed by Step 4.
END
DESCRIPTION
Y=2000-2007 Time Pattern No. 0-7
•
(1)
XX ZZ: Time to Change
XX: 00-23: Hours
ZZ: 00/30: Minutes
(2)
0000-0255: Route Pattern No. 000-255
If Tenant Pattern is required, set 1000-1015
(Tenant Pattern No. 00-15).
Y=0000-0255
•
Route Pattern No. 000-255
(1)
1
(2)
XXX 00
XXX: 000-255: TR Pattern No.
Y=5000-5255 TR Pattern No.
•
(1)
000
(2)
00-15: Trunk Restriction Pattern No.
00-15
– 531 –
TOLL RESTRICTION-3/6-DIGIT
DATA
A2523-10